Related Experiment Video
Updated: May 17, 2026

The Microscopic Transcanal Approach in Stapes Surgery Revisited
Published on: February 16, 2022
System B, Endo-Twinn and E-Fill. True temperatures inside the canal
Enzo Cumbo1, Riccardo Russo, Giuseppe Gallina
1Department of Surgical Oncology, University of Palermo, Section of Oral Science, Palermo, Italy.
Background:
The aim of this study is to verify the variations of the temperature inside the root canal with three different gutta-percha heating systems.
Materials And Methods:
A split-tooth model was built with a lateral groove at 3.5-mm from working length (WL) in order to insert a Chromel-Alumel K-type thermocouple placed in contact with gutta-percha. The thermocouple was connected to a digital thermometer. Sixty obturations were made with medium gutta-percha points. For 20 specimens the System B was used with the Buchanan fine plugger and the temperature was set at 200°C; for other 20 specimens the Endo-Twinn with a fine plugger was used and for the last 20 specimens we used the E-Fill with a 40.04 plugger. All pluggers were pushed to 3.5 mm from WL so that the tips were in contact to the probe.
Results:
The analysis of 60 samples showed the highest temperature average using the System B after 10 seconds (86.85°C), after 15 seconds (94.9°C), after 20 seconds (100.4°C) and after 25 seconds (104.5°C). The Endo-Twinn average values are similar to System-B ones. The E-Fill average values are lower (69.9°C) than the other two systems evaluated only after 10 seconds due to limited working time. The temperatures average obtained using different systems of warm vertical compaction are lower than what was declared by the producing companies.
Conclusion:
Time is one the most important parameters to consider using these systems. Temperatures reached from the System B and Endo-Twinn after 25 seconds; however, seem to be sufficient to ensure an optimal adaptation of the gutta-percha in the anatomical complexity of root canals. The temperatures obtained from the E-Fill, only after 10 seconds, instead seems to be insufficient to assure the rheological characteristics of gutta-percha.
Related Concept Videos
Assessing Body Temperature - Tympanic membrane
Step 1: Begin by practicing good hand hygiene to prevent the transmission of microorganisms.
Step 2: Turn on the thermometer and wait until the ready sign appears on the screen to ensure accurate measurement.
Step 3: Slide the probe cover in place to prevent cross-contamination.
Step 4: Instruct the patient to tilt their head to the side for comfort and check for cerumen...
Assessing Body Temperature - Oral
Step 1:
Start by practicing proper hand hygiene to prevent the spread of microorganisms.
Step 2:
Take the thermometer out of the charging unit, switch it on, and wait for the ready sign.
Step 3:
Gently slide the probe cover until a click is heard. This simple action prevents cross-contamination and ensures the correct placement of the probe cover.
Step 4:
Instruct the patient to open their mouth and place...
Temperature Measurement Sites
Oral: When assessing oral temperature, the thermometer tip should be placed under the tongue in the posterior sublingual pocket. It offers accurate readings and can be...
Assessing Body Temperature - Temporal Artery
Step 1: Perform hand hygiene and don a fresh pair of gloves to prevent cross-infection and ensure patient safety.
Step 2: Explain the procedure to the patient to establish trust. Clear communication establishes trust with the patient, ensures they understand what to expect, promotes cooperation, and enhances comfort during the procedure.
Step 3: Assess the patient's forehead...
Assessing Body Temperature - Rectal
Follow these steps for rectal temperature assessment:
Step 1: Perform hand hygiene and don clean gloves to prevent cross-infection.
Step 2: Position the patient in a side-lying position to better visualize the rectal...
Equipments Used to Measure Body Temperature
Glass-bulb Thermometer:
Glass-bulb thermometers are hollow glass tubes with a bulb tip containing liquid such as ethanol or mercury. Historically, glass bulb mercury thermometers were the standard device to measure body temperature. Today, mercury thermometers are prohibited in many countries due to the hazardous effects of mercury and the risk of exposure if the glass bulb breaks. In general,...