Related Experiment Video
Updated: May 17, 2026

The Use of Mixed Reality in Custom-Made Revision Hip Arthroplasty: A First Case Report
Published on: August 4, 2022
Revision hip arthroplasty with a modular cementless stem: mid-term follow up
Stefan R Jibodh1, Ran Schwarzkopf, Shawn G Anthony
1Department of Orthopaedic Surgery, Kaiser Permanente - Walnut Creek, CA, USA.
Abstract:
Despite the increasing volume of revision total hip arthroplasty (THA) being performed in the United States, there are few studies reporting mid-term clinical and radiographic outcomes of modular fully porous-coated femoral stems. We retrospectively studied a consecutive series of patients who underwent revision THA with a modular extensively porous-coated femoral component at a single institution and by a single surgeon. The final study group included 54 hips (52 patients) followed for an average of 84 months. Ten-year survival rates with revision for any reason and revision for femoral loosening as endpoints were 94% and 100%, respectively. No complications regarding the modular junction were encountered. Of the 50 hips with adequate radiographs, all showed proximal ingrowth and 42 (84%) had both proximal and distal ingrowth. The modular, fully porous-coated femoral stem studied demonstrated excellent survivorship and bone ingrowth at mid-term follow up.