Related Experiment Video
Updated: May 17, 2026

Standardized Technique of Aortic Valve Re-implantation for Valve-sparing Aortic Root Replacement
Published on: December 11, 2017
Valve replacement via upper partial sternotomy for quadricuspid aortic valve
Yukiharu Sugimura1, Masanori Katoh, Takashi Murakami
1Department of Cardiovascular Surgery, Fuji Heavy Industries Health Insurance Society Ota Memorial Hospital, 455-1 Oshima-cho, Ota, Gunma 373-8585, Japan. sugiharu0204@gmail.com
Abstract:
A 52-year-old man was referred to our clinic because of chronic heart failure. A Levine 3/6 diastolic heart murmur was audible at the apex. Chest radiography showed an enlarged left ventricle. Transthoracic echocardiography showed moderately severe aortic regurgitation. Left ventricular end-diastolic/systolic diameter and ejection fraction were 75/59 mm and 41 %, respectively. Preoperative transesophageal 3-dimensional echocardiography revealed a quadricuspid aortic valve whose cusps were of almost equal size. Aortic valve replacement was performed via upper partial sternotomy.
More Related Videos
Related Concept Videos
Mitral Stenosis III: Medical Management
Aortic Regurgitation III: Medical Management