Related Experiment Video
Updated: May 17, 2026

Topical Airway Anesthesia for Awake-endoscopic Intubation Using the Spray-as-you-go Technique with High Oxygen Flow
Published on: January 13, 2017
Hydrogen peroxide as 'defogger' in indirect laryngoscopy
Sudhakar Vaidya1, R S Pagare, S K Jethaliya
1R D Gardi Medical College & Ujjain Charitable Trust Hospital, D-3/2, Dhanvantari Nagar, Near Mahananda Nagar, Ujjain (MP), India.
Hydrogen peroxide 0.75% solution effectively prevents mirror fogging during indirect laryngoscopy. This safe and cost-effective method improves visualization of the larynx and hypopharynx for clinicians.
Area of Science:
- Otolaryngology
- Medical Devices
- Clinical Procedures
Background:
- Indirect laryngoscopy is essential for examining the larynx and hypopharynx.
- Mirror fogging during indirect laryngoscopy can impede visualization.
- Existing defogging methods have limitations.
Purpose of the Study:
- To evaluate hydrogen peroxide 0.75% w/v solution as a defogging agent for indirect laryngoscopy mirrors.
- To determine the safety and cost-effectiveness of this defogging method.
Main Methods:
- Indirect laryngoscopy examination was performed.
- A 0.75% w/v hydrogen peroxide solution was applied to the mirror as a defogging agent.
- Clinical observations on defogging efficacy and safety were recorded.
Main Results:
- The 0.75% hydrogen peroxide solution effectively prevented mirror fogging during indirect laryngoscopy.
- The defogging agent was found to be safe for clinical use.
- The method was identified as cost-effective.
Conclusions:
- Hydrogen peroxide 0.75% w/v solution is a safe and effective defogging agent for indirect laryngoscopy.
- This method offers a practical and economical solution to improve visualization during laryngeal examinations.
Related Concept Videos
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...
Oxygen Delivering System III: Tracheostomy and T-piece
Tracheostomy
A tracheostomy is a surgically created opening (stoma) in the anterior part of the trachea. It is used to establish a patient airway, bypass an upper airway obstruction, simplify the removal of secretions, permit long-term...
Endoscopic Studies I: Bronchoscopy and Thoracoscopy
Bronchoscopy
Description
Bronchoscopy is a procedure that involves direct visualization of the larynx, trachea, and bronchi for diagnostic and therapeutic purposes. A flexible fiber optic or rigid bronchoscope is used to carry out the procedure. The fiber-optic bronchoscope is more frequently used due to...
Autoxidation of Ethers to Peroxides and Hydroperoxides
Tracheostomy Suctioning I: Pre-Procedural Steps
Equipment Required
First, gather all necessary equipment: a sterile suction catheter, a sterile disposable container, sterile gloves, a towel or...
PPE Use in Healthcare Settings II: Doffing