Related Experiment Video
Updated: May 17, 2026

Generation of Electronic Cigarette Aerosol by a Third-Generation Machine-Vaping Device: Application to Toxicological Studies
Published on: August 25, 2018
Bacterial contamination of multiple-use atomizers commonly used in Japan
Katsuhisa Ikeda1, Yoko Sakai, Takuo Haruyama
1Department of Otorhinolaryngology, Juntendo University School of Medicine, Tokyo, 113 8421 Japan.
Abstract:
Before performing transnasal fiberscopy to observe the nasal cavity, pharynx and larynx in outpatient clinics, nasal anesthetics and vasoconstrictive agents are routinely sprayed into the nares in order to improve patients' comfort. Bacterial contamination of the nozzles of Venturi principle atomizer barrels and their solutions after being used for multiple patients over a long-term period without cleaning is controversial. We evaluated the potential risk of atomizer-associated cross-infection by using atomizers commonly available in Japan that use compressed air to atomize medication. Eighteen of the 23 samples (78.3%) from the external nozzle tips of the atomizers resulted in positive bacterial cultures. These detected bacteria are suggested to be colonized in the nares and to cause bacterial contamination of the atomizer. Of the 25 samples obtained from the spray of the drug solutions, 11 samples showed positive bacterial culture, whereas 16 control samples produced no growth of bacteria. The present study demonstrated that the atomizer widely used in the outpatient ENT clinics in Japan has a potential risk of causing cross-infection of patients.
More Related Videos
08:33Use of Capillary Aerosol Generator in Continuous Production of Controlled Aerosol for Non-Clinical Studies
Published on: April 12, 2022
09:30A Microcontroller Operated Device for the Generation of Liquid Extracts from Conventional Cigarette Smoke and Electronic Cigarette Aerosol
Published on: January 18, 2018
Related Concept Videos
Atomic Absorption Spectroscopy: Atomization Methods
Types of Toxins
Air pollutants, primarily gases, pose significant threats to respiratory health, leading to conditions like hypoxia, lung cancer, and in extreme cases, death.
Environmental pollutants like...
Vaporization
Atomic Absorption Spectroscopy: Interference
Spectral interference occurs when signals from other elements or molecules overlap with the analyte signal, falsely elevating or masking the analyte's absorbance. This interference can be corrected using Zeeman,...
Stimulants
Cocaine can be administered via snorting, injection, or smoking. It primarily functions by blocking the reuptake of dopamine, resulting in a euphoric high characterized by an intense sensation of happiness and...
Atomic Emission Spectroscopy: Instrumentation