Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Ion-Specific Effects on PuO<sub>2</sub> Nanoparticle Aggregation and Dissolution in Concentrated Electrolytes.

Langmuir : the ACS journal of surfaces and colloids·2026
Same author

Black Hole Spectroscopy and Tests of General Relativity with GW250114.

Physical review letters·2026
Same author

GW250114: Testing Hawking's Area Law and the Kerr Nature of Black Holes.

Physical review letters·2025
Same author

Current challenges in intrauterine management of obstructive fetal hydrocephalus and future directions.

Ultrasound in obstetrics & gynecology : the official journal of the International Society of Ultrasound in Obstetrics and Gynecology·2025
Same author

MEK inhibition induces expression of differentiation marker Keratin 10 in human keratinocytes.

Pathology, research and practice·2023
Same author

SPECT/CT imaging of inflammation and calcification in human carotid atherosclerosis to identify the plaque at risk of rupture.

Journal of nuclear cardiology : official publication of the American Society of Nuclear Cardiology·2021
Same journal

Effective contrast-enhanced preprocessing for intracranial artery segmentation in digital subtraction angiography.

Physics in medicine and biology·2026
Same journal

Improving Plan Quality in Adaptive Proton Therapy Using an Interactive Dose Modification Tool.

Physics in medicine and biology·2026
Same journal

Technical Note: Real-Time MLC Control and Latency Measurement Optimization with External Verification.

Physics in medicine and biology·2026
Same journal

Fetus-Specific Hematopoietic Stem Cell Dosimetry Framework for Leukemia-Relevant Target Cells During Prenatal Development.

Physics in medicine and biology·2026
Same journal

Deep learning-based dose prediction to enhance planning efficiency in cervical brachytherapy with hybrid applicators.

Physics in medicine and biology·2026
Same journal

Corrigendum: Referenceless MR thermometry-a comparison of five methods (2017<i>Phys. Med. Biol</i>.<b>62</b>1-16).

Physics in medicine and biology·2026
See all related articles

Related Experiment Video

Updated: May 17, 2026

Whole-cell Super-Resolution Imaging via DNA-PAINT on a Spinning Disk Confocal with Optical Photon Reassignment
07:12

Whole-cell Super-Resolution Imaging via DNA-PAINT on a Spinning Disk Confocal with Optical Photon Reassignment

Published on: January 6, 2026

Improved EMCCD gamma camera performance by SiPM pre-localization.

S Salvador1, M A N Korevaar, J W T Heemskerk

  • 1Department of Radiation Radionuclides and Reactors, Applied Sciences, Delft University of Technology, JB Delft, The Netherlands.

Physics in Medicine and Biology
|November 6, 2012
PubMed
Summary
This summary is machine-generated.

This study introduces a novel hybrid camera combining electron-multiplying charge-coupled devices (EMCCDs) and silicon photomultipliers (SiPMs) for enhanced gamma-ray imaging. The new system significantly improves signal-to-background ratio and energy resolution while maintaining high spatial resolution.

More Related Videos

Three-dimensional Super Resolution Microscopy of F-actin Filaments by Interferometric PhotoActivated Localization Microscopy (iPALM)
11:57

Three-dimensional Super Resolution Microscopy of F-actin Filaments by Interferometric PhotoActivated Localization Microscopy (iPALM)

Published on: December 1, 2016

Test Samples for Optimizing STORM Super-Resolution Microscopy
16:52

Test Samples for Optimizing STORM Super-Resolution Microscopy

Published on: September 6, 2013

Related Experiment Videos

Last Updated: May 17, 2026

Whole-cell Super-Resolution Imaging via DNA-PAINT on a Spinning Disk Confocal with Optical Photon Reassignment
07:12

Whole-cell Super-Resolution Imaging via DNA-PAINT on a Spinning Disk Confocal with Optical Photon Reassignment

Published on: January 6, 2026

Three-dimensional Super Resolution Microscopy of F-actin Filaments by Interferometric PhotoActivated Localization Microscopy (iPALM)
11:57

Three-dimensional Super Resolution Microscopy of F-actin Filaments by Interferometric PhotoActivated Localization Microscopy (iPALM)

Published on: December 1, 2016

Test Samples for Optimizing STORM Super-Resolution Microscopy
16:52

Test Samples for Optimizing STORM Super-Resolution Microscopy

Published on: September 6, 2013

Area of Science:

  • Nuclear physics
  • Medical imaging instrumentation
  • Radiation detection

Background:

  • Electron-multiplying charge-coupled devices (EMCCDs) offer high spatial resolution for gamma imaging but are susceptible to noise.
  • Silicon photomultipliers (SiPMs) have been previously used to reject false-positive EMCCD events using sum signals.

Purpose of the Study:

  • To develop and evaluate a next-generation hybrid camera integrating individual SiPM signals with EMCCD readout.
  • To enhance gamma-ray imaging by improving event discrimination and energy resolution.

Main Methods:

  • Utilized individual SiPM signals and maximum likelihood estimation (MLE) for pre-localization to distinguish true from false events in CCD frames.
  • Employed SiPM signals for improved energy discrimination.
  • Tested the hybrid detector with a CsI:Tl crystal at 140 keV.

Main Results:

  • Achieved a signal-to-background ratio (SBR) improvement of 5.9, 4.0, or 2.2 with MLE pre-localization (1.06 mm accuracy), at the cost of rejecting 47%, 9%, or 4% of events, respectively.
  • Improved energy resolution from 50% to (19 ± 3)% by combining pre-localization and SiPM energy estimation.
  • Maintained spatial resolution at 180 µm.

Conclusions:

  • The hybrid CCD-SiPM camera effectively discriminates true events and enhances gamma-ray imaging performance.
  • This technology offers significant improvements in signal-to-background ratio and energy resolution for scintillator-based detectors.