[Brain tissue water content determination based on T1 relaxation time of water and quantitative cerebral 1H MRS at 3T
Györgyi File1, Gábor Bajzik, Tamás Dóczi
1Pécsi Tudományegyetem, Altalános Orvostudományi Kar, Idegsebészeti Klinika, Pécs.
Objective:
Application of a quantitative MR-spectroscopic method for 3T clinical scanners based on tissue water content as an internal reference.
Patients And Methods:
Six (22 +/- 2 yrs) volunteers were involved in the study. We performed T1 relaxation time measurements in a particular slice of the brain at 1T and 3T. Based on the validated water content measurement at 1T, the correlation of relaxation time T1 and water content was determined at 3T. The resulting water content served as internal reference for the quantification of localizated MR-spectroscopic measurement.
Results:
At 3T our method resulted in 37.6 +/- 0.5 mol/l and 46.4 +/- 1.5 mol/l tissue water content in the white and gray matter, respectively. Calibration based on water content led to following metabolite concentrations: N-acetyl-aspartate 7.79 +/- 0.67 mmol/l; creatine 3.76 +/- 0.28 mmol/l; choline 3.68 +/- 0.47 mmol/l; myo-inositol 10.35 +/- 3.70 mmol/l in the white matter; and N-acetyl-aspartate 8.20 +/- 0.45 mmol/l; creatine 4.76 +/- 0.18 mmol/l; choline 2.64 +/- 0.35 mmol/l; myo-inositol 8.32 +/- 1.42 mmol/l in the grey matter.
Conclusions:
Tissue water content based on T value at 3T shows good accordance with gravimetric or other MR methods in the literature. Using it as an internal reference resulted in white matter metabolite concentrations that are in the range of previously published data. Comparing metabolite values of grey matter is more difficult because data in the literature substantially differ. The presented method is simple and easily applicable on any MR scanner without complicated correction and calibration steps.
More Related Videos
09:30Quantitative Magnetic Resonance Imaging of Skeletal Muscle Disease
Published on: December 18, 2016
13:56The Use of Magnetic Resonance Spectroscopy as a Tool for the Measurement of Bi-hemispheric Transcranial Electric Stimulation Effects on Primary Motor Cortex Metabolism
Published on: November 19, 2014
Related Concept Videos
Magnetic Resonance Imaging
Chemical Shift: Internal References and Solvent Effects
The internal reference compound generally used in NMR spectroscopy is tetramethylsilane (TMS). TMS is preferred because it is chemically inert, soluble in NMR solvents, and easily removable. Also, the highly shielded methyl protons in TMS yield an intense...