M J Lanctot1, C T Holcomb, S L Allen
1Lawrence Livermore National Laboratory, Livermore, California 94550, USA. lanctot1@llnl.gov
Abstract:
Temperature-controlled, 0.15 nm interference filters were installed on an edge-viewing system of the motional Stark effect (MSE) polarimeter on the DIII-D tokamak. The upgraded system provides a factor of two reduction in the bandpass compared to the previous design, and linear control of the bandpass, which is unaltered by wavelength tuning. With the new system, there is a reduced dependence of the inferred polarization angle on the filter wavelength calibration. Recent measurements from the calibrated edge-viewing system show increased agreement with other MSE arrays.
Related Concept Videos
Magnetic Fields
A magnetic field is defined by the force that a charged particle experiences...
The Hall Effect
Magnetic Field due to Moving Charges
Consider a point charge moving with a constant velocity. Like the electric field, the magnetic field at any point is directly proportional to the magnitude of the charge and inversely proportional to the square of the distance between the source point and the field point. However, unlike the electric field, the magnetic field is always perpendicular to the plane containing the line...
Motional Emf
Magnetic Damping
If, however, the bob is a slotted metal plate, the magnet produces a much smaller effect. When a slotted metal plate enters the field, an emf is induced by the change in flux; however, it is less effective because the slots limit the...
Potential Due to a Magnetized Object
The vector...