Clinical application of a novel automatic algorithm for actigraphy-based activity and rest period identification to accurately determine awake and asleep ambulatory blood pressure parameters and cardiovascular risk
Related Experiment Video
Updated: May 17, 2026

Collecting Sleep, Circadian, Fatigue, and Performance Data in Complex Operational Environments
Published on: August 8, 2019
Cristina Crespo1, José R Fernández, Mateo Aboy
1Department of Electrical Engineering & Renewable Energy, Oregon Institute of Technology,27500 SW Parkway Ave., Wilsonville, OR 97070 USA. cristina.crespo@oit.edu
Abstract:
This paper reports the results of a study designed to determine whether there are statistically significant differences between the values of ambulatory blood pressure monitoring (ABPM) parameters obtained using different methods-fixed schedule, diary, and automatic algorithm based on actigraphy-of defining the main activity and rest periods, and to determine the clinical relevance of such differences. We studied 233 patients (98 men/135 women), 61.29 ± .83 yrs of age (mean ± SD). Statistical methods were used to measure agreement in the diagnosis and classification of subjects within the context of ABPM and cardiovascular disease risk assessment. The results show that there are statistically significant differences both at the group and individual levels. Those at the individual level have clinically significant implications, as they can result in a different classification, and, therefore, different diagnosis and treatment for individual subjects. The use of an automatic algorithm based on actigraphy can lead to better individual treatment by correcting the accuracy problems associated with the fixed schedule on patients whose actual activity/rest routine differs from the fixed schedule assumed, and it also overcomes the limitations and reliability issues associated with the use of diaries.
Related Concept Videos
Pre-Procedural Guidelines for Assessing Blood Pressure
Assessment of blood pressure in brachial artery(one-step method)
Prepare for the Procedure:
Assessment of blood pressure in brachial artery(two-step method)
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.