1King's Mill Hospital, Mansfield Road Sutton in Ashfield, Nottinghamshire NG17 4JL, UK. edbayley12@gmail.com
Introduction:
Complex fracture dislocations of the midfoot are uncommon. Improved outcomes have been demonstrated where it has been possible to restore and maintain the length and alignment of the medial column as well as the congruity of the articular surfaces. We present our experience with the use of angle-stable locking plates in the stabilisation of complex midfoot fracture dislocations.
Methods:
Twelve patients were identified on a prospective trauma database between 2003 and 2009. All fractures involved the medial column with four associated fracture subluxations of the lateral column also. Patients underwent open reduction internal fixation (ORIF) with restoration of the medial column axis, reduction of the articular surface congruity and stabilisation with angle-stable locking plates.
Results:
There were no post-operative infections or neurological injuries. Ten of the twelve patients required metalwork removal. There were no implant failures prior to removal of the metalwork. At a mean follow-up of 12.4 months (range: 4-32 months), 11 patients had minimal symptoms of swelling, discomfort or stiffness in the midfoot. This did not restrict their daily activities. One patient developed post-traumatic arthritis and collapse of the medial longitudinal arch. Two patients declined removal of the metalwork.
Conclusions:
Angle-stable locking plates provide satisfactory stabilisation following ORIF of complex midfoot fracture dislocations. Most patients will require removal of the metalwork. Following removal of metalwork, the majority of patients will maintain the length, alignment and stability of the midfoot.
More Related Videos
04:41Treatment with Locking Intramedullary Nailing for Intertrochanteric Fracture of the Femur Utilizing a New Awl with a Distal Positioner
Published on: June 6, 2025
07:41An Intramedullary Locking Nail for Standardized Fixation of Femur Osteotomies to Analyze Normal and Defective Bone Healing in Mice
Published on: November 13, 2016
Related Concept Videos
Fractures: Bone Repair
Minor fractures with no bone displacement are treated by immobilizing the fractured bone using a cast or splint. However, in the case of fractures with displaced bones, the broken bones are repositioned before immobilization to ensure successful healing without deformation and loss of function. The realignment of fractured bone ends is performed through a process called reduction. If the procedure...
Frictional Forces on Screws
A jack with a square-threaded screw is a mechanical device used to lift heavy loads by applying a force at its handle. When the force is applied, the screw turns, raising the load. The screw can...
Wedges
Consider using a wedge to lift a heavy slab. Here, the wedge functions by converting the applied force into a much larger force directed almost perpendicular to the initial force. This...