[Study of venous inflow and outflow using mercury gauge venous occlusion plethysmography during pregnancy]

P Lermusiaux1, H Derriennic, L Castellani

  • 1Service de Chirurgie Cardio-vasculaire, Hôpital Trousseau, Tours.

Changes due to hormone activity and caval compression by the uterus were noted in venous hemodynamics of the lower limbs during pregnancy. The purpose of the study was to search for a possible incidence of these modifications on venous inflow ant outflow during mercury strain gauge plethysmography (fig. 1). A total of 183 subjects were distributed into 4 groups: (table I) nonpregnant women of childbearing age (controls = C) and women of the first (G1), second (G2) and third (G3) trimesters of gestation. Women with a history of phlebitis or pronounced varicosis were excluded. The figures for venous filling (table II, III et IV) (delta V) were 3.2 (C), 3.1 (G1), 2.64 (G2) and 2.04 (G3). There was a significant (P less than 0.001) reduction in G3 (and left-sided G2) delta V compared to that of controls. Maximum venous outflow (MVO) was 125.3 (G1), 123.7 (G2) and 123.5 (G3), showing no significant difference with controls (125.1). It is concluded that no significant change in MVO occurred during pregnancy, whereas there was a decrease in delta approximately greater than V during the third trimester. These results suggest that the latter parameter should not be considered as a criterion for diagnosis of phlebitis in the pregnant woman.

Related Concept Videos

Sites for measuring blood pressure01:21

Sites for measuring blood pressure

Blood pressure measurement is a fundamental clinical procedure, providing crucial data for assessing cardiovascular health. Among the various sites for this measurement, the brachial and popliteal arteries are predominantly utilized due to their accessibility and the reliability of their readings. This lesson delves into the anatomical significance, methodology, and considerations of measuring blood pressure at these locations.
The Brachial Artery: Primary Site for Blood Pressure Measurement
Equipments Used To Measure Blood Pressure01:30

Equipments Used To Measure Blood Pressure

Direct Method
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Assessing Blood pressure using a doppler ultrasound01:19

Assessing Blood pressure using a doppler ultrasound

To obtain accurate blood pressure measurements in clinical settings, especially when traditional methods are insufficient, healthcare professionals utilize the Doppler ultrasound technique. This method uses high-frequency sound waves to detect blood flow within the arteries, which is crucial for patients with conditions that complicate circulatory system assessment.
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Measurement of Blood Pressure01:17

Measurement of Blood Pressure

Assessing blood pressure is a standard procedure executed in virtually all medical environments. The method utilized today was established over a hundred years ago by an innovative Russian doctor, Dr. Nikolai Korotkoff. The soft ticking noise, known as Korotkoff sounds, heard while taking blood pressure readings results from turbulent blood flow within the vessels. The apparatus required for this procedure includes a sphygmomanometer, a blood pressure cuff attached to a gauge, and a stethoscope.
Venous Return01:04

Venous Return

The circulatory system plays a crucial role in ensuring the optimal functioning of the human body. One of its critical components is venous return - the process that completes the blood circulation cycle. This article will delve into the concept of venous return, how it works, and its significance to our health.
What is Venous Return?
Venous return refers to the rate at which blood flows back to the heart from the body's peripheral veins. It's an integral part of the circulatory system as it...
Venous Thrombosis II: Clinical Manifestations and Diagnostic Studies01:20

Venous Thrombosis II: Clinical Manifestations and Diagnostic Studies

The key difference between Superficial Vein Thrombosis (SVT) and Deep Vein Thrombosis (DVT) lies in their location and severity.Clinical ManifestationsSVT typically presents with localized pain, tenderness, and redness along the course of a superficial vein, often accompanied by a palpable, cord-like structure under the skin. This condition is usually less dangerous than DVT but can be uncomfortable and may lead to complications such as cellulitis or, rarely, a clot extension into the deep...