Reagent-less electrogenerated chemiluminescence peptide-based biosensor for the determination of prostate-specific
Honglan Qi1, Chen Wang, Xiaoying Qiu
1Key Laboratory of Analytical Chemistry for Life Science of Shaanxi Province, School of Chemistry and Chemical Engineering, Shaanxi Normal University, Xi'an 710062, PR China. honglanqi@snnu.edu.cn
Abstract:
A novel electrogenerated chemiluminescence peptide-based (ECL-PB) biosensor for highly sensitive and selective determination of prostate-specific antigen (PSA) was developed. A helix peptide (CHSSKLQK) was served as a molecular recognition element and ruthenium bis(2,2'-bipyridine) (2,2'-bipyridine-4,4'-dicarboxylic acid)-N-hydroxysuccinimide ester (Ru(bpy)(2)(dcbpy)NHS) was used as an ECL label. The helix peptide was labeled with the ECL label at NH(2)-containing lysine and utilized as ECL probe (Ru-peptide). The ECL-PB biosensor was fabricated by immobilizing the ECL probe onto a gold electrode surface via self-assembling technique through a thiol-containing cysteine at the end of the peptide. The principle of ECL measurement is based on the specific proteolytic cleavage event of Ru-peptide on the gold electrode surface in the presence of PSA, resulting in a decrease of ECL signal. The decreased ECL intensity was directly linear to the concentration of PSA in the range from 1.0×10(-10) g/mL to 8.0×10(-9) g/mL with a detection limit of 3.8×10(-11) g/mL. This work demonstrates that the direct transduction of peptide cleavage events into an ECL signal provides a simple and sensitive method for detecting target protein.