Related Experiment Video
Updated: May 17, 2026

Transdermal Measurement of Glomerular Filtration Rate in Mice
Published on: October 21, 2018
GFR estimation using standardized cystatin C in kidney transplant recipients
Ingrid Masson1, Nicolas Maillard, Ivan Tack
1Service de Néphrologie Dialyse Transplantation rénale, CHU Hopital Nord, Saint-Etienne, France.
Background:
The utility of serum cystatin C (SCysC) as a filtration marker in kidney transplantation is uncertain. We took advantage of the recent validation of a reference calibrator for SCysC and of newly developed CKD-EPI (Chronic Kidney Disease Epidemiology Collaboration) equations (2012) expressed for use with standardized SCysC level to reassess the performance of SCysC as a filtration marker in kidney transplant recipients.
Study Design:
Study of diagnostic test accuracy.
Setting & Participants:
670 kidney transplant recipients from 3 centers undergoing glomerular filtration rate (GFR) measurements from December 2006 to November 2012.
Index Test:
Estimated GFR (eGFR) using the 2012 SCysC-based and serum creatinine (SCr)/SCysC-based CKD-EPI equations (eGFR(cys) and eGFR(cr-cys), respectively) and the 2009 SCr-based CKD-EPI equation (eGFR(cr)), with SCysC and SCr measured at a single laboratory between April 2011 and June 2011.
Reference Test:
Measured GFR (mGFR) using urinary clearance of inulin.
Results:
Bias (the difference between mGFR and eGFR) was significantly smaller for eGFR(cys) and eGFR(cr-cys) versus eGFR(cr) (-2.82 and -0.54 vs +4.4 mL/min/1.73 m(2), respectively; P < 0.001). Precision (standard deviation of the mean bias) also was better for eGFR(cys) and eGFR(cr-cys) versus eGFR(cr) (12 and 11 vs 13 mL/min/1.73 m(2) [P < 0.001 for both comparisons]). Accuracy (percentage of GFR estimates within 30% of mGFR) was greater for eGFR(cys) and eGFR(cr-cys) versus eGFR(cr) (81% and 86% vs 75%, respectively [P = 0.004 and P < 0.001]). Net reclassification index with respect to mGFR of 30 mL/min/1.73 m(2) for eGFR(cr-cys) and eGFR(cys) versus eGFR(cr) was 18.8% [95% CI, 8.6%-28.9%] and 22.5% [95% CI, 10.2%-34.9%].
Limitations:
Patients were exclusively of European descent; association with transplant outcome was not evaluated.
Conclusions:
Our data validate the use of both the newly developed SCysC-based and SCr/SCysC-based CKD-EPI equations (2012) in kidney transplant recipients. Both equations perform better than the SCr-based CKD-EPI equation (2009).
Related Concept Videos
Drug Dosing in Renal Diseases: Measurement of Glomerular Filtration Rate
Drug Dosing in Renal Diseases: Estimation of Glomerular Filtration Rate Based on Serum Creatinine Concentration
Drug Dosing in Renal Diseases: Measurement of Serum Creatinine Concentration and Clearance
Factors Affecting Renal Clearance: Renal Impairment
One condition associated with renal failure is uremia. Uremia is characterized by impaired glomerular filtration and fluid accumulation in the body. This condition hinders the renal clearance of drugs, resulting in drug accumulation and potential...
Renal Clearance
Renal clearance refers to the volume of plasma cleared of a specific substance, such as creatinine, per unit of time. To measure clearance, urine samples are collected over a 24-hour period during each bladder voiding, followed by a single blood sample at the...
Kidney Transplant II: Surgical Procedure