Electron Channeling Contrast Imaging for Rapid III-V Heteroepitaxial Characterization
Published on: July 17, 2015
Simulation of the backscattered electron intensity of multi layer structure for the explanation of secondary electron
1Research Institute for Technical Physics and Materials Science, Budapest H-1525, P.O. Box 49, Hungary.
Abstract:
The intensities of the secondary electrons (SE) and of the backscattered electrons (BSE) at energy 100 eV have been measured on a Ni/C/Ni/C/Ni/C/(Si substrate) multilayer structure by exciting it with primary electrons of 5, 2.5 and 1.25 keV energies. It has been found that both intensities similarly vary while thinning the specimen. The difference as small as 4 nm in the underlying layer thicknesses resulted in visible intensity change. Utilizing this intensity change, the thickness difference of neighboring regions could be revealed from the SE image. No simple phenomenological model was found to interpret the change of intensity, thus the intensity of the BSE electrons has been calculated by means of a newly developed Monte Carlo simulation. This code also considers the secondary electron generation and transport through the solid. The calculated and measured intensities agree well supporting the validity of the model.
More Related Videos
11:14Comprehensive Characterization of Extended Defects in Semiconductor Materials by a Scanning Electron Microscope
Published on: May 28, 2016
06:49In situ Grazing Incidence Small Angle X-ray Scattering on Roll-To-Roll Coating of Organic Solar Cells with Laboratory X-ray Instrumentation
Published on: March 2, 2021
Related Concept Videos
Scanning Electron Microscopy
Fundamental Principles
Accelerated...
Overview of Electron Microscopy
Transmission Electron Microscopy
Electron Microscope Tomography and Single-particle Reconstruction
Electron Tomography
Electron tomography can be performed either in TEM or STEM (scanning transmission...
Preparation of Samples for Electron Microscopy
Phase Contrast and Differential Interference Contrast Microscopy
In-phase-contrast microscopes, interference between light directly passing through a cell and light refracted by cellular components is used to create high-contrast, high-resolution images without staining. It is the oldest and simplest type of microscope that creates an image by altering the wavelengths of light rays passing through the specimen. Altered wavelength paths are created using an annular stop in the condenser. The annular stop produces a hollow cone of...