Related Experiment Video
Updated: May 16, 2026

Analysis of 18FDG PET/CT Imaging as a Tool for Studying Mycobacterium tuberculosis Infection and Treatment in Non-human Primates
Published on: September 5, 2017
Diagnostic yield of FDG positron-emission tomography/computed tomography in patients with CEID infection: a pilot
Jennifer Cautela1, Stephane Alessandrini, Serge Cammilleri
1Department of Cardiology, La Timone Hospital, CHU La Timone, 264, Rue Saint Pierre, 13005 Marseille, France.
Aims:
Whole body imaging with (18)F-fluorodeoxyglucose positron-emission tomography/computed tomography (FDG PET/CT) has proven useful in various infectious diseases. The purpose of this pilot study was to assess the diagnostic yield of FDG PET/CT in patients with cardiac implantable electronic device (CIED) infection.
Methods And Results:
A total of 21 patients with CIED infection were prospectively included. Diagnosis of CIED infection was made in accordance with current criteria. It was classified in three categories, i.e. superficial skin infection, pocket site infection, or cardiac device-related infective endocarditis (CDRIE). All patients underwent FDG PET/CT. Scans were interpreted blindly, i.e. without prior knowledge of diagnosis, by experienced nuclear medicine physicians. The accuracy of FDG PET/CT was assessed for each diagnostic category. Findings demonstrated superficial skin infection in 1 patient, pocket site infection in 15, and CDRIE in 13 (definite: 7; possible: 6). In patients with pocket site infection, the sensitivity and specificity of FDG PET/CT were 86.7% [59.5-98.3, 95% confidence interval (CI)] and 100% [42.1-100, 95% CI]. The only patient with superficial skin infection was accurately identified by FDG PET/CT. The sensitivity and specificity of FDG PET/CT in patients with CDRIE were 30.8% [9.1-61.4, 95% CI] and 62.5% [24.5-91.5, 95% CI]. Most false-negative results occurred in patients who had undergone previous antimicrobial treatment.
Conclusion:
This study indicates that FDG PET/CT is highly accurate for the diagnosis of skin and pocket CIED infection but low for infective endocarditis. This suggests that the reliability of FDG PET/CT findings in management decision making varies according to the type of CIED infection.
More Related Videos
Related Concept Videos
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body being...
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...

![Semi-quantitative Assessment Using [18F]FDG Tracer in Patients with Severe Brain Injury](/_next/image?url=https%3A%2F%2Fcloudfront.jove.com%2FCDNSource%2Fteasers%2F58641.jpg&w=3840&q=50)