Related Experiment Video
Updated: May 16, 2026

A Multicenter MRI Protocol for the Evaluation and Quantification of Deep Vein Thrombosis
Published on: June 2, 2015
[Dose area product of pediatric VCUG with regard to the strongly lowered German diagnostic reference levels]
1Radiologische Klinik - Kinderradiologie, Universität Bonn. mark.born@ukb.uni-bonn.de
Purpose:
To compare the dose area products of pediatric VCUG in daily practice with the dramatically reduced official German diagnostic reference levels, which are based on selected data.
Materials And Methods:
413 consecutive pediatric VCUG examinations were analyzed.
Results:
The mean dose area product of all examinations was 0.97 dGycm². This is below the lowest reference level that is valid for neonates. In 12 cases (5.6 %) the achieved dose area product was higher than the corresponding reference level.
Conclusion:
Using the available techniques for radiation protection, it is possible in the daily routine to meet the official diagnostic reference levels for children, which have been reduced by up to 80 %, even though these levels are based on a selected, possibly non-representative data set.
More Related Videos
Related Concept Videos
Drug Dosing: Infants and Children
Drug Dosing in Renal Diseases: Measurement of Glomerular Filtration Rate
Dose Size and Dosing Frequency: Determination Methods
Dosage Regimens: Partial Pharmacokinetic Parameters
Imaging Studies VI: Voiding Cystourethrography and Cystography
Pharmacokinetics in Pediatric Patients: Drug Excretion