Cardiac output measured by uncalibrated arterial pressure waveform analysis by recently released software version
Cornelis Slagt1, Marcel A de Leeuw, Jan Beute
1Zaans Medical Centre, Koningin Julianaplein 58, Postbus 210, 1500 EE, Zaandam, The Netherlands. Slagtc@gmail.com
Abstract:
To evaluate the 3.02 software version of the FloTrac/Vigileo™ system for estimation of cardiac output by uncalibrated arterial pressure waveform analysis, in septic shock. Nineteen consecutive patients in septic shock were studied. FloTrac/Vigileo™ measurements (COfv) were compared with pulmonary artery catheter thermodilution-derived cardiac output (COtd). The mean cardiac output was 7.7 L min(-1) and measurements correlated at r = 0.53 (P < 0.001, n = 314). In Bland-Altman plot for repeated measurements, the bias was 1.7 L min(-1) and 95 % limits of agreement (LA) were -3.0 to 6.5 L min(-1), with a %error of 53 %. The bias of COfv inversely related to systemic vascular resistance (SVR) (r = -0.54, P < 0.001). Above a SVR of 700 dyn s cm(-5) (n = 74), bias was 0.3 L min(-1) and 95 % LA were -1.6 to 2.2 L min(-1) (%error 32 %). Changes between consecutive measurements (n = 295) correlated at 0.67 (P < 0.001), with a bias of 0.1 % (95 % limits of agreement -17.5 to 17.0 %). All changes >10 % in both COtd and COfv (n = 46) were in the same direction. Eighty-five percent of the measurements were within the 30°-330° of the polar axis. COfv with the latest software still underestimates COtd at low SVR in septic shock. The tracking capacities of the 3.02 software are moderate-good when clinically relevant changes are considered.
Related Concept Videos
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Cardiac Output and Stroke Volume
In an average resting adult male, the typical cardiac...
Measurement of Blood Pressure
Cardiac Output II: Effect of Stroke Volume on Cardiac Output
Preload
Preload refers to the initial elongation of the cardiac myocytes before contraction and is related to the volume of blood filling the heart at the end of diastole, or end-diastolic volume. The...