Non-invasive Optical Measurement of Cerebral Metabolism and Hemodynamics in Infants
Published on: March 14, 2013
[The analysis for improving the SNR of blood components noninvasive measurement with DS method]
Gang Li1, Hui-quan Wang, Zhe Zhao
1State Key Laboratory of Precision Measurement Technology and Instruments, Tianjin University, Tianjin 300072, China. ligang59@tju.edu.cn
Abstract:
In order to increase the accuracy of blood components measurement and enhance the stability of prediction model, the quantitative signal-noise-ratio (SNR) analysis of measuring instruments based on dynamic spectrum (DS) and preprocessing method was conducted. The SNR of DS is increased after adding boxcar integrator, decreasing wavelength revolution, balancing the DS's SNR and excluding gross errors in preprocessing according to experiment results. Two volunteers were tested continuously for many times using the DS data acquiring system. The correlation coefficients of the each volunteer's DS data was increased from 0.934 and 0.953 to 0.991 and 0.987, respectively. Moreover, the gap between the correlation coefficient of the same volunteer's DS and different volunteers' DS is increased too, which shows that the SNR can be improved by these methods. The quantitative SNR analysis can guide the way of choosing preprocessing method efficiently, which will create the condition for clinical application of the blood components noninvasive measurement.
More Related Videos
14:28Non-Invasive Monitoring of Microvascular Oxygenation and Reactive Hyperemia using Hybrid, Near-Infrared Diffuse Optical Spectroscopy for Critical Care
Published on: May 10, 2024
09:28Using Laser Doppler Imaging and Monitoring to Analyze Spinal Cord Microcirculation in Rat
Published on: May 30, 2018
Related Concept Videos
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Assessment of blood pressure in brachial artery(two-step method)