Related Experiment Video
Updated: May 16, 2026

Photoelectron Imaging of Anions Illustrated by 310 Nm Detachment of F−
Published on: July 27, 2018
Universal anion detection by replacement-ion chromatography with an atmospheric-pressure solution-cathode glow
Andrew J Schwartz1, Zheng Wang, Steven J Ray
1Department of Chemistry, Indiana University, Bloomington, 47405, United States.
Abstract:
A new method of detection for ion chromatography (IC) is described that couples replacement-ion chromatography (RIC) with an atmospheric-pressure solution-cathode glow discharge (SCGD). In the new instrument, a conventional suppressed IC arrangement is followed by a "replacement column" that consists of a cation-exchange micromembrane suppressor continuously regenerated with Li(2)SO(4). In this arrangement analytes are stoichiometrically converted to Li salts when they pass through the replacement column and are introduced into the SCGD, where they are detected indirectly by atomic emission spectrometry. Though found to be unsuitable for cation determinations, the SCGD-RIC instrument shows good repeatability (<3.5% peak area relative standard deviation), approximately 4 orders of linear dynamic range, universal calibration (similar molar sensitivity for anions of the same charge), and detection limits between 0.08 and 0.64 μg·mL(-1) (25-μL injection) for several mono- and divalent anions. Deviations from the universal calibration were also observed and are critically evaluated. Optimal operating conditions are described, analytical figures of merit are presented, and background sources present in the system are characterized and explained.
More Related Videos
07:32Detection of 3-Nitrotyrosine in Atmospheric Environments via a High-performance Liquid Chromatography-electrochemical Detector System
Published on: January 30, 2019
12:48Measuring Cation Transport by Na,K- and H,K-ATPase in Xenopus Oocytes by Atomic Absorption Spectrophotometry: An Alternative to Radioisotope Assays
Published on: February 19, 2013
Related Concept Videos
Gas Chromatography: Types of Detectors-II
High-Performance Liquid Chromatography: Types of Detectors
Gas Chromatography: Types of Detectors-I
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...
Ion-Exchange Chromatography
Gas Chromatography: Overview of Detectors
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...
Atomic Emission Spectroscopy: Instrumentation