Background:
Magnetic resonance imaging studies have reported that lithium can increase the volume of gray matter in the human brain, a finding that has been ascribed to the established neurotrophic or neuroprotective effects of the drug. Lithium, however, might directly influence the intensity of the magnetic resonance signal so it is possible that the volumetric findings are artifactual, essentially a consequence of altered image contrast.
Methods:
Anatomical and quantitative magnetic resonance scans were acquired on 31 healthy young men before and after taking either lithium or placebo for 11 days. Brain volume change was derived with two established techniques: voxel-based morphometry (a statistical approach using signal intensity to segment images into tissue types), and Structural Image Evaluation, using Normalization, of Atrophy (a technique that operates by detecting changes in the position of the boundaries of the brain). In a subgroup (n = 12), tissue-specific magnetic resonance relaxation times were compared before and after lithium with quantitative T1-mapping techniques.
Results:
Voxel-based morphometry revealed that gray matter volume was increased by lithium but not placebo (p = .001), whereas Structural Image Evaluation, using Normalization, of Atrophy showed no difference between lithium and placebo (p = .23). Taking lithium reduced the T1 relaxation of the gray matter only (p = .008).
Conclusion:
Magnetic resonance images of the brain differ before and after lithium, but this difference might derive from a change in the characteristics of the signal rather than a tangible increase in volume.
More Related Videos
13:56The Use of Magnetic Resonance Spectroscopy as a Tool for the Measurement of Bi-hemispheric Transcranial Electric Stimulation Effects on Primary Motor Cortex Metabolism
Published on: November 19, 2014
08:16High-resolution Structural Magnetic Resonance Imaging of the Human Subcortex In Vivo and Postmortem
Published on: December 30, 2015
Related Concept Videos
Magnetic Resonance Imaging
Brain Imaging
These technologies include computerized axial tomography (CAT or CT scans), positron-emission tomography (PET scans), magnetic resonance imaging (MRI), functional magnetic resonance imaging (fMRI), and Transcranial Magnetic Stimulation (TMS).
Imaging Studies IV: Magnetic Resonance Imaging