Related Experiment Video
Updated: May 16, 2026

Analysis of Organochlorine Pesticides in a Soil Sample by a Modified QuEChERS Approach Using Ammonium Formate
Published on: January 20, 2023
Optimization of matrix solid phase dispersion coupled with gas chromatography electron capture detection for
Amir Salemi1, Elham Shafiei, Maryam Vosough
1Environmental Sciences Research Institute (ESRI), Shahid Beheshti University, G.C., Evin, Tehran 1983963113, Iran. amirsalemi@gmail.com
Abstract:
A fast, simple and efficient technique based on matrix solid phase dispersion has been presented for extraction and clean-up of some chlorinated pesticides and derivative products; α-BHC, β-BHC, γ-BHC, δ-BHC, heptachlor, aldrin, dieldrin, endrin, endosulfan 1, endosulfan 2, 4,4'-DDT, 4,4'-DDE, 4,4'-DDD, heptachlor epoxide, endrin aldehyde, endosulfan sulfate. Box-Behnken response surface methodology was employed for optimization of the extraction efficiency. As the optimized procedure, 0.5 g of dried and sieved soil samples were mixed with 2.0 g of 10% C18 in silica (w/w) as dispersant and after transferring into the extraction tube they were extracted with 8 mL of dichloromethane-n-hexane (1:1, v/v). Gas chromatography with electron capture detector was used for selective and sensitive determination of the analytes. Recoveries for the extraction of the proposed analytes were calculated and were satisfying (more than 75%), except for endrin aldehyde (59%) and endosulfan sulfate (62%). Also the method was linear over the calibration range (R(2)>0.991) and the quantitative results were reasonably reproducible and sensitive (LODs ranged between 0.3 and 1.8 ng g(-1)).
More Related Videos
08:56Detection of Regulated Ergot Alkaloids in Food Matrices by Liquid Chromatography-Trapped Ion Mobility Spectrometry-Time-of-Flight Mass Spectrometry
Published on: November 22, 2024
05:31Gas Chromatography-Mass Spectrometry Paired with Total Vaporization Solid-Phase Microextraction as a Forensic Tool
Published on: May 25, 2021
Related Concept Videos
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a column.
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall. The coating...
Gas Chromatography: Types of Detectors-II
High-Performance Liquid Chromatography: Types of Detectors
Gas Chromatography: Types of Columns and Stationary Phases
For an analyte to remain on the column for a sufficient amount of time, it must exhibit some level of compatibility (or...
Gas Chromatography: Overview of Detectors
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...