Noninvasive determination of arterial elasticity and blood pressure. Part II: elastogram and blood pressure
1Department of Behavioral Neurobiology, Institute of Neurobiology, Bulgarian Academy of Sciences, Sofia, Bulgaria. antonova@bio.bas.bg
Objective:
The oscillometric method is used in the medical practice for measurement of arterial blood pressure and, rarely, for estimation of arterial elasticity. In the previous paper of this series, the relations between arterial volume pulsations and volume-to-pressure curve (elastogram) were examined resolving the problem for evaluation of arterial volume pulsations from known elastogram and systolic (ps)/diastolic (pd) blood pressure. Some features were found that are considered to be elastogram attributes. The aim of the present work is to resolve the inverse problem - graphical reconstruction of the elastogram from oscillometric data and determination of blood pressure.
Participants And Methods:
The elastograms of an idealized arterial model as well as of experimental oscillometric records (five men, five women) are processed graphically.
Results:
The method for reconstruction is developed with the idealized volume pulsations of the arterial model, establishing full correspondence of the elastogram fixed in the model with those determined here. The accuracy of this reconstruction is assessed: a pulse pressure variability of 12% leads to an ~2-9% error of the reconstructed elastogram. Thereafter, experimental elastograms are reconstructed graphically, and the correct pulse pressure and blood pressure are determined. The experimentally determined blood pressure is statistically compared with that simultaneously auscultatory measured. Satisfactory correspondence between values of ps/pd is found. A method of objective comparison between elastograms after normalization is suggested.
Conclusion:
A novel graphical, nonempirical method for a noninvasive reconstruction of the elastogram and determination of blood pressure is presented. The method can be applied easily in automated blood pressure measurement devices.
Related Concept Videos
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Assessment of blood pressure in brachial artery(two-step method)
Measurement of Blood Pressure
Sites for measuring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement
Assessment of blood pressure in brachial artery(one-step method)
Prepare for the Procedure:
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment: