Related Experiment Video
Updated: May 16, 2026

Evaluation of Fluid Overload by Bioelectrical Impedance Vectorial Analysis
Published on: August 17, 2022
Assessing the influence of insulation on intravenous fluid infusion temperature
Jonathan R Studnek1, John A Watts, Steven Vandeventer
1The Center for Prehospital Medicine, Carolinas Medical Center, Charlotte, NC, USA. jonst@medic911.com
Objectives:
Inducing therapeutic hypothermia using chilled saline in resuscitated cardiac arrest patients has been shown to be feasible and effective. Limited research exists assessing the efficiency of this cooling method. The objective of this study was to assess the change in temperature of 4°C saline upon exiting an infusion set in the laboratory setting while varying conditions of fluid delivery.
Methods:
Efficiency was studied by assessing change in fluid temperature (°C) during the infusion under four laboratory conditions. Each condition was performed four times using 1-L bags of normal saline. Fluid was infused into a 1000-mL beaker through 10 gtt/mL tubing. Flow rate was controlled using a tubing clamp and in-line transducer with a flow meter, while temperature was continuously monitored in a side port at the terminal end of the intravenous (IV) tubing using a digital thermometer. The four conditions included different insulation methods. Descriptive statistics and analysis of variance were performed to assess changes in fluid temperature.
Results:
The mean (±SD) fluid temperature at time 0 was 3.2°C (95% confidence interval [CI] = 3.0 to 3.4 °C) with no significant difference in starting temperature between groups (p = 0.45). When flow rate was constant, it was determined that fluid temperatures were significantly cooler when infused using a chilled, gel-filled sleeve around the saline bag (p < 0.006).
Conclusions:
In a laboratory setting, the most efficient method of infusing cold fluid appears to be a method that both keeps the bag of fluid insulated and infused at a faster rate.
Related Concept Videos
Assessing Body Temperature - Oral
Step 1:
Start by practicing proper hand hygiene to prevent the spread of microorganisms.
Step 2:
Take the thermometer out of the charging unit, switch it on, and wait for the ready sign.
Step 3:
Gently slide the probe cover until a click is heard. This simple action prevents cross-contamination and ensures the correct placement of the probe cover.
Step 4:
Instruct the patient to open their mouth and place...
One-Compartment Model: IV Infusion
The one-compartment model for IV infusion uses mathematical equations to describe the rate of change in drug quantity in the body. At steady-state or infusion equilibrium, the drug input...
Factors Affecting Body Temperature
Factors may include:
Decreased Body Temperature
Assessing Body Temperature - Rectal
Follow these steps for rectal temperature assessment:
Step 1: Perform hand hygiene and don clean gloves to prevent cross-infection.
Step 2: Position the patient in a side-lying position to better visualize the rectal...
Assessing Body Temperature - Axilla
Step 1: Perform hand hygiene and put on clean gloves to maintain infection control and prevent cross-contamination.
Step 2: Prepare the patient by explaining the procedure to ensure understanding and cooperation. Ensure privacy, expose the axilla, and inform the patient that minimal movement is crucial for an accurate reading.
Step 3: Adjust the patient’s clothing to expose only the axilla. It minimizes...