Related Experiment Video
Updated: May 16, 2026

Remote Magnetic Navigation for Accurate, Real-time Catheter Positioning and Ablation in Cardiac Electrophysiology Procedures
Published on: April 21, 2013
Loss of pace capture after radiofrequency application predicts the formation of uniform transmural lesions
Ioanna Kosmidou1, Haley Houde-Walter, Lori Foley
1Department of Cardiology, Brigham and Women's Hospital, 75 Francis Street, Boston, MA 02115, USA. ioanna.kosmidou@piedmont.org
Aims:
Lesion transmurality is critical to procedural success in radiofrequency catheter ablation. We sought to determine whether loss of pace capture (PC) with high-output unipolar and/or bipolar pacing predicts the formation of uniform transmural lesions.
Methods And Results:
Ten juvenile swine were anaesthetized and prepped under sterile conditions. Seventy-seven isolated radiofrequency applications (RFAs) using a 3.5 mm tip-irrigated catheter were available for analysis. Pace capture was assessed before and after RFA at 10 mA/2 ms and catheter stability verified with a three-dimensional mapping system. Pace capture was defined as 1 : 1 or intermittent local capture per paced beat. Myocardial contact and catheter orientation were assessed using intracardiac echo. Endocardial and epicardial lesion areas were measured after sacrifice using 2,3,5-triphenyltetrazolium chloride staining. A uniform transmural lesion was defined as an epicardial-to-endocardial surface ratio (epi/endo) ≥ 76%. Seventy-four per cent of lesions were transmural and 55.8% of lesions had an epi/endo ratio ≥ 76%. In all, 79.2% of lesions associated with loss of bipolar PC were uniform whereas 20.8% of lesions with loss of bipolar PC were non-uniform (P = 0.006). Loss of bipolar PC was associated with higher mean epicardial/endocardial ratio compared with lesions with persistent PC (P = 0.019). Echocardiographic evidence of optimal catheter contact during RFA improved the predictive accuracy of uniform lesion formation when loss of bipolar PC was noted after RFA.
Conclusion:
Loss of bipolar PC after RFA is associated with the formation of uniform lesions in atrial tissue. Optimal catheter contact further improves the predictive accuracy associated with loss of PC.
More Related Videos
06:57Ablation of Ischemic Ventricular Tachycardia Using a Multipolar Catheter and 3-dimensional Mapping System for High-density Electro-anatomical Reconstruction
Published on: January 31, 2019
09:24Multiparametric Optical Mapping of the Langendorff-perfused Rabbit Heart
Published on: September 13, 2011