Related Experiment Video
Updated: May 16, 2026

High-throughput and Comprehensive Drug Surveillance Using Multisegment Injection-Capillary Electrophoresis-Mass Spectrometry
Published on: April 23, 2019
Screening approach, optimisation and scale-up for chiral liquid chromatography of cathinones
R Wimal H Perera1, Ijeoma Abraham, Shradha Gupta
1Sunderland Pharmacy School, Sciences Complex, Dale Building, University of Sunderland, Sunderland SR1 3SD, UK.
Abstract:
Screening approaches adopted in pharmaceutical companies for chiral LC method development may be quite complicated and sophisticated in order to guarantee a high success rate. However in other environments it may be of more value to assess how simple a screen might be used to still have a good chance of achieving success. The genuine need to develop chiral separations for the former 'legal-high' drug mephedrone and related cathinones of topical interest presented a good opportunity to develop this theme. In initial work on mephedrone itself, no chiral separation was observed on Chirobiotic V, Cyclobond I 2000 DNP, Whelk-O1 and AmyCoat using reversed phase mobile phases. However, using normal phase solvents, chiral separation was observed on all the chiral stationary phases (CSP) used except Chiralcel OJ-H. Of the chiral separations observed on RegisPack, RegisCell and Whelk-O1, some optimisation work was carried out on the latter two which had showed the greatest enantioselectivity. Following optimisation, the best enantioselectivity (1.59) and enantioresolution (5.90) was found with a 250 mm × 4.6 mm I.D. Whelk-O1 column using a propan-2-ol (IPA)-hexane-trifluoroacetic acid (TFA)-triethylamine (TEA) (10:90:0.05:0.05, v/v/v/v) mobile phase. Subsequent screening on other cathinones was restricted to RegisPack, RegisCell and Whelk-O1 or equivalent phases with two mobile phases and this gave a very good success rate. Indeed it was possible to separate all six cathinones on one column, RegisCell, with one mobile phase, propan-2-ol-hexane-TFA (15:85:0.1, v/v/v) but obviously it had been necessary to go through the 3-column screen to arrive at this finding. While Whelk-O1 was not so successful, ease of optimisation on this phase was again a feature. To illustrate the applicability of these separations, it was shown that, as a basis for semi-preparative work, the optimsed mephedrone separation on Whelk-O1 could be scaled-up to a 2000μl injection of a 1.0 mg ml(-1) solution in mobile phase (2.0mg on-column) while still using the 250 mm × 4.6 mm I.D. analytical column.
Related Concept Videos
Optimizing Chromatographic Separations
Band broadening refers to spreading solute bands as they travel through the column. This broadening can impact resolution. Plate height (H) represents the length required for one theoretical plate. A lower plate height corresponds to...
High-Performance Liquid Chromatography: Introduction
In HPLC, two phases play a critical role in the separation process:
Principles Of Column Chromatography
Size-Exclusion Chromatography
Silica particles offer advantages such as rigidity,...
High-Performance Liquid Chromatography: Elution Process
Supercritical Fluid Chromatography
SFC utilizes a supercritical fluid mobile phase,...