Development, optimization, and use of an APCI source with temperature-controlled vaporization of solid and liquid
Sonja Krieger1, Alexandra von Trotha, Kelvin Sze-Yin Leung
1Institute for Pure and Applied Mass Spectrometry, University of Wuppertal, Wuppertal, Germany.
Abstract:
A trend is observed in mass spectrometry, in which solid samples without prior dissolution and chromatographic separation are brought directly into the ion source and are ionized, e.g., by corona discharge (Atmospheric Solids Analysis Probe) or plasma (Direct Analysis in Real Time). The Direct Inlet Probe-atmospheric-pressure chemical ionization (APCI) ion source presented here, which was coupled to a high-resolution quadrupole time-of-flight-mass spectrometer, differs from most of the other ion sources in having temperature-programmed heating of the sample. The resulting possibility to reduce ion suppression and ion-molecule reactions in the ion source was shown by the separation of two fatty acid methyl esters as a result of their boiling point difference. Using caffeine as sample, certain source parameters such as the auxiliary gas flow, the drying gas flow, and the position of the probe tip in the ion source were optimized. The ability to perform quantitative analyses was shown by the linear concentration response (R(2) = 0.9984) observed when analyzing different caffeine concentrations. An extract of a Chinese medicinal herb was used to examine the reproducibility (relative standard deviations of the most abundant m/z signals were ≤8.1 %). It was also possible to distinguish milled samples of Radix Angelicae sinensis and Radix Angelicae gigas from each other and to identify the coumarins they contain without sample preparation. Supplying synthetic air instead of nitrogen to the ion source makes APCI in the negative mode possible as well; this was proven by the analysis of n-nonyl-β-D-maltoside.
Related Concept Videos
Inductively Coupled Plasma Atomic Emission Spectroscopy: Principle
The ions and electrons produced interact with the fluctuating magnetic field created by a water-cooled...
Inductively Coupled Plasma–Mass Spectrometry (ICP–MS): Overview
Gas Chromatography: Sample Injection Systems
Two primary injection methods are used...
Atomic Absorption Spectroscopy: Atomization Methods
Sample Preparation for Analysis: Advanced Techniques
Acid digestion with strong acids is commonly used to dissolve inorganic materials that are insoluble (do not dissolve) in water. This method can be useful for...
Sample Handling
Samples should be transported carefully from collection points to the laboratory. They should be properly sealed and clearly labeled to prevent cross-contamination. To preserve the sample integrity, optimal temperature conditions during transport are essential. This could involve using...