Screening of Axonal Degeneration in Carpal Tunnel Syndrome Using Ultrasonography and Nerve Conduction Studies
Published on: January 11, 2019
Provocation tests in doppler ultrasonography for carpal tunnel syndrome
Esther S Ng1, Kay W Ng, Einar P Wilder-Smith
1Department of Medicine, National University Health System, Heidelberg, Germany.
Introduction:
Doppler ultrasonography (DU) has recently been shown to be useful in imaging carpal tunnel syndrome (CTS). In this study, we aim to characterize the changes seen after exercise and electrical stimulation.
Methods:
Five patients with CTS were recruited with 5 age-matched subjects. DU was used to visualize the median nerve, flexor tendon, and bone at base line and after 1 minute of: (a) median nerve motor stimulation, (b) median nerve sensory stimulation, (c) abductor pollicis brevis contraction, and (d) adductor digiti minimi contraction.
Results:
Blood flow in the median nerve was greater after APB exercise. Furthermore, blood flow in the median nerve was greater in cases than controls after APB exercise. At baseline, blood flow in the flexor tendon was greater in cases than controls.
Conclusions:
While limited by sample size, this study demonstrates that exercise of median innervated muscles may be useful in enhancing diagnostic utility of DU for CTS.
Related Concept Videos
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Peripheral Arterial Disease II: Clinical Manifestations and Diagnostic Evaluation
Assessment of the Cardiovascular System III: Palpation
Jugular Venous Pressure (JVP) Measurement
Position the patient at a thirty- to forty-five-degree angle or in a semi-fowler's position. Look for the highest point of pulsation in the internal jugular vein and measure the vertical distance to the angle of Loius or sternal angle. A normal JVP is 3-4 cm above the...
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Assessment of apical radial pulse
The A-R pulse assessment involves simultaneous evaluation of the apical and radial pulses. When the apical and radial pulse rates vary, this assessment helps identify a pulse deficit.
Pre-Procedural Preparation
Assessment of radial pulse
The radial pulse, located at the wrist, is often the preferred site for assessing peripheral pulse because of its accessibility and dependability. The process of determining the radial pulse involves several steps: