Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Gut microbiota transfer from autoimmune dry eye mice imprints stereotypic B cell receptor repertoires in the lacrimal gland and induces disease.

Frontiers in immunology·2026
Same author

Spatial multi-omics reveals region-specific molecular signatures in a 6-OHDA model of Parkinson's disease.

NPJ Parkinson's disease·2026
Same author

A large-scale vision foundation model for musculoskeletal radiographs.

NPJ digital medicine·2026
Same author

Spatially resolved osteoblast-traced transcriptomics uncovers TGF-β as a combination target with sclerostin in osteoporosis.

Bone research·2026
Same author

Correction: Sequential trench well based microfluidic platform to isolate bacteria from whole blood with large volume processing.

Lab on a chip·2025
Same author

Deep Learning Model for Differentiating Between Neoplastic Pathologic Fracture and Nonpathologic Fracture Using Hip Radiographs.

The Journal of bone and joint surgery. American volume·2025
Same journal

The ACS at 150: The History of Analytical Chemistry Publications and a Century of Progress.

Analytical chemistry·2026
Same journal

Machine Learning-Enabled Image Analysis of Complex Chemical Mixtures: Synthetic Urine Droplets as a Test System.

Analytical chemistry·2026
Same journal

H<sub>2</sub>O<sub>2</sub>/Viscosity Tandem-Locked Fluorescent Probes Based on an In Situ Fluorophore Synthesis Strategy for Colitis Imaging and Diagnosis.

Analytical chemistry·2026
Same journal

TopoStitcher: A Geometric-Topological Structure-Guided Stitching Framework for Single-Molecule Localization Microscopy.

Analytical chemistry·2026
Same journal

Noninvasive SERS Immunosensing of Tyrosinase for Melanoma Monitoring via Microneedle Sampling Integrated with Satellite-Structured Bifunctional Nanozymes.

Analytical chemistry·2026
Same journal

Label-Free Electrochemical CRISPR Platform Gated by Allosteric Transcription Factors for Ultrasensitive Small-Molecule Detection.

Analytical chemistry·2026
See all related articles

Related Experiment Video

Updated: May 16, 2026

A Microfluidic Chip for the Versatile Chemical Analysis of Single Cells
15:41

A Microfluidic Chip for the Versatile Chemical Analysis of Single Cells

Published on: October 15, 2013

Potentiometric multichannel cytometer microchip for high-throughput microdispersion analysis.

Junhoi Kim1, Eun-Geun Kim, Sangwook Bae

  • 1Department of Electrical Engineering and Computer Science, Seoul National University, Korea.

Analytical Chemistry
|November 28, 2012
PubMed
Summary
This summary is machine-generated.

This study presents a novel microfluidic cytometer that overcomes signal crosstalk in parallel channels. This innovation enables high-throughput, low-cost cell analysis for point-of-care diagnostics.

More Related Videos

Microfluidic Platform with Multiplexed Electronic Detection for Spatial Tracking of Particles
11:54

Microfluidic Platform with Multiplexed Electronic Detection for Spatial Tracking of Particles

Published on: March 13, 2017

Multimodal Analytical Platform on a Multiplexed Surface Plasmon Resonance Imaging Chip for the Analysis of Extracellular Vesicle Subsets
06:12

Multimodal Analytical Platform on a Multiplexed Surface Plasmon Resonance Imaging Chip for the Analysis of Extracellular Vesicle Subsets

Published on: March 17, 2023

Related Experiment Videos

Last Updated: May 16, 2026

A Microfluidic Chip for the Versatile Chemical Analysis of Single Cells
15:41

A Microfluidic Chip for the Versatile Chemical Analysis of Single Cells

Published on: October 15, 2013

Microfluidic Platform with Multiplexed Electronic Detection for Spatial Tracking of Particles
11:54

Microfluidic Platform with Multiplexed Electronic Detection for Spatial Tracking of Particles

Published on: March 13, 2017

Multimodal Analytical Platform on a Multiplexed Surface Plasmon Resonance Imaging Chip for the Analysis of Extracellular Vesicle Subsets
06:12

Multimodal Analytical Platform on a Multiplexed Surface Plasmon Resonance Imaging Chip for the Analysis of Extracellular Vesicle Subsets

Published on: March 17, 2023

Area of Science:

  • Biomedical Engineering
  • Analytical Chemistry
  • Microfluidics

Background:

  • Microfluidic cytometry offers enhanced throughput for point-of-care diagnostics.
  • Parallelized microfluidic channels face interchannel signal crosstalk due to electrical coupling.
  • Existing methods require complex setups to mitigate crosstalk.

Purpose of the Study:

  • To develop a microfluidic potentiometric multichannel cytometer with parallel analysis capabilities.
  • To address and eliminate interchannel signal crosstalk in microfluidic cytometry.
  • To achieve high-throughput and low-cost cell analysis.

Main Methods:

  • Development of a microfluidic potentiometric multichannel cytometer.
  • Implementation of a triple-electrode configuration within each detection channel to electrically decouple units.
  • Validation using polystyrene microbeads and bacterial samples (Bacillus subtilis).

Main Results:

  • The triple-electrode configuration successfully eliminated interchannel signal crosstalk.
  • Parallel analysis was demonstrated on a 16-channel potentiometric cytometer with minimal cross-correlation (|r| < 0.13).
  • A detection throughput of approximately 48,000 events per second was achieved.

Conclusions:

  • The developed triple-electrode microfluidic cytometer effectively enables crosstalk-free parallel analysis.
  • This technology facilitates high-throughput and low-cost cytometry, suitable for point-of-care applications.
  • The methodology's scalability allows for further throughput increases with greater parallelism.