Related Experiment Video
Updated: May 16, 2026

Microparticle Manipulation by Standing Surface Acoustic Waves with Dual-frequency Excitations
Published on: August 21, 2018
Proof of principle study of ultrasonic particle manipulation by a circular array device
Alon Grinenko1, Paul D Wilcox, Charles R P Courtney
1Department of Mechanical Engineering , University of Bristol , Bristol BS8 1TR, UK.
Abstract:
A feasibility study of a circular ultrasonic array device for acoustic particle manipulation is presented. A general approach based on Green's function is developed to analyse the underlying properties of a circular acoustic array. It allows the size of a controllable device area as a function of the number of array elements to be established and the array excitation required to produce a desired field distribution to be determined. A set of quantitative parameters characterizing the complexity of the pressure landscape is suggested, and relation to the number of array elements is found. Next, a finite-element model of a physically realizable circular piezo-acoustic array device is employed to demonstrate that the trapping capability can be achieved in practice.
More Related Videos
10:14Fabrication and Operation of Acoustofluidic Devices Supporting Bulk Acoustic Standing Waves for Sheathless Focusing of Particles
Published on: March 6, 2016
09:21Experiments on Ultrasonic Lubrication Using a Piezoelectrically-assisted Tribometer and Optical Profilometer
Published on: September 28, 2015