Related Experiment Video
Updated: May 16, 2026

Quasistatic Mechanical Testing for Computer-Aided Design and Manufacturing Occlusal Veneers Cemented to Milled Dentin Analog Material
Published on: December 20, 2024
Effect of loading on the microtensile bond strength and microleakage of a self-etching and etch-and-rinse adhesive in
Theodora Bravis1, Peter Pilecki, Ron F Wilson
1Restorative Dentistry Department, King’s College London Dental Institute, King’s College London, Guy’s Hospital, London, SE1-9RT UK.
Abstract:
The effect of loading on microleakage and microtensile bond strength of MOD composite restorations bonded with either self-etching or etch-and-rinse adhesive was investigated. MOD cavities were prepared in 28 extracted molar teeth. 14 teeth were bonded with a one-step self-etching adhesive (G-Bond) and 14 with an etch-and-rinse adhesive (Optibond Solo Plus) then restored with resin composite. For each adhesive, 7 teeth were loaded and 7 unloaded (controls). Loading was achieved with an axial force of 80 N at 2.5 cycles/s for 250,000 cycles. All the teeth were stored in 0.25% rhodamine solution for 24 h and sectioned in a bucco-lingual direction at the proximal boxes to examine microleakage then further sliced mesiodistally into beams for the microTBS test. Failure modes were determined using confocal and scanning electron microscopy. ANOVA assessed the effect of loading on microleakage and bond strength. After loading, restorations bonded with G-Bond exhibited significantly greater dye penetration compared to Optibond Solo Plus at both the axial walls and cavity floor. On the other hand, loading significantly reduced the microTBS of Optibond Solo Plus, whereas it had no significant effect on the microTBS of G-Bond.