Background:
The aim of this study was measurement of the radiation doses received by patients for common radiology examinations in hospitals under control of Isfahan University of Medical Sciences, Iran.
Materials And Methods:
THERMOLUMINESCENCE (LITHIUM FLUORIDE CHIPS, LIF: Mg, Tl) dosimeter was used to measure patient dose for four (chest, posterior-anterior and lateral and skull anterior-posterior, or posterior-anterior and lateral) common radiographic views in six hospitals (seven X-ray machines). The entrance surface dose was measured on 20 randomly patients for each X-ray room.
Results:
The maximum (8.85 ± 0.62 mGy) and the minimum (0.62 ± 0.22 mGy) values of ESD was obtained for X-ray machines of Shimadzu and Varian located in Ashrafi-Khomeini-shahr and Kashani hospitals, respectively. As results shows, the values of ESD of skull were higher than that of chest examinations.
Conclusion:
The results of this study indicated that ESD measured doses were slightly greater than the ICRP and NRPB reference doses. Efforts should be made to further lower patient doses while securing image quality. In addition, the need to provide relevant education and training to staff in the radiology sections is of utmost importance.
Related Concept Videos
Radiological Investigation I: X-ray and CT
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Radiological Investigation II: MRI and Ventilation Perfusion Scan
Magnetic Resonance Imaging (MRI) and Ventilation Perfusion Scans are two radiological investigations that offer detailed diagnostic images of the body, particularly lung structures.
MRI
MRI uses magnetic fields and radiofrequency signals to distinguish between normal and abnormal tissues. This technology provides a more detailed diagnostic image than CT scans, enabling it to characterize pulmonary nodules, stage bronchogenic carcinoma, and evaluate inflammatory activity in...
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Imaging Studies for Cardiovascular System III: X-Ray
Definition and Purpose
An X-ray, or radiograph, is a non-invasive method that uses ionizing radiation to take images of internal structures. It is mainly used in cardiac imaging to examine the heart, lungs, and major blood vessels, aiming to identify abnormalities in the heart's size, shape, and position, such as heart failure, congenital defects, and vascular...