Related Experiment Video
Updated: May 16, 2026

Point-of-Care Ultrasound for Peripheral Veno-Arterial Extracorporeal Membrane Oxygenation Without Left Ventricular Venting
Published on: January 17, 2025
A new formula for determining arterial oxygen saturation during venovenous extracorporeal oxygenation
Elmi Messaï1, Abdesselam Bouguerra, Guy Harmelin
1Service de réanimation, Centre hospitalier de Cholet, 1 rue Marengo BP 507, 49325 Cholet, France. elmi.messai@ch-cholet.fr
Purpose:
Venovenous extracorporeal membrane oxygenation (VV-ECMO) is used to treat severe forms of acute respiratory distress syndrome (ARDS). VV-ECMO management may be confusing due to the lack of information about the interplay between the determinant parameters and their impact on oxygenation. We found a relationship between arterial oxygen saturation (SaO(2)) and its relevant parameters. The aim of this study was to assess the validity of this model.
Methods:
We report our experience in 17 patients under VV-ECMO for severe ARDS. We compared, at two different levels of pump flow, SaO(2) and the oxygen saturation measured in the pulmonary artery (SpaO(2)) with the predicted saturation using the formula: SpaO(2) = (EF/CO)SmO(2) + (1 - EF/CO)SvO(2) + 10(-2)PmO(2), where PF is pump flow, R is recirculation, EF is effective flow [= (1 - R)PF], SmO(2) is saturation of the oxygenator outgoing blood, CO is cardiac output, SvO(2) is saturation of mixed venous blood, and PmO(2) is oxygen partial pressure of the oxygenator outgoing blood.
Results:
There was no significant difference between predicted and measured SpaO(2): the mean predicted and measured SpaO(2) values were 90.7 ± 2.8 % and 90.4 ± 2.7 % , respectively (p = 0.696, r = 0.966). Bland-Altman analysis showed good agreement between predicted and measured SpaO(2). Predicted SpaO(2) and SaO(2) was well correlated (r = 0.80).
Conclusions:
We have presented an explicit relationship between SaO(2) and its direct determinants during VV-ECMO. Good agreement was found with the measured values of SaO(2), but the model remains to be fully validated before its use in clinical practice.
Related Concept Videos
Special considerations while measuring oxygen saturation
Ensuring accuracy in vital sign recordings while prioritizing patient comfort and minimizing anxiety is important.
Assessment of Diffusion and Perfusion
The Role of Diffusion in Respiration
Diffusion is the process by which molecules move from an area of higher concentration to an area of lower concentration. In the respiratory system, this principle...
Pulse Oximetry
Purpose
Average SpO2 values are greater than 95%. If the readings fall below 90%, it indicates that...
Guidelines For Measuring Vital Signs
Before taking a patient's vital signs, a nurse would consider and assess the patient's comfort level and ensure appropriate equipment is available.
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...
Oxygen Transport in the Blood