Related Experiment Video
Updated: May 16, 2026

08:53
Angle-resolved Photoemission Spectroscopy At Ultra-low Temperatures
Published on: October 9, 2012
Observation of picometer vertical emittance with a vertical undulator
K P Wootton1, M J Boland, R Dowd
1School of Physics, The University of Melbourne, Melbourne VIC 3010, Australia. k.wootton@student.unimelb.edu.au
Physical Review Letters
|December 11, 2012
Summary
Picometer vertical electron beam emittances were observed using a novel undulator diagnostic at the Australian Synchrotron. This method is sensitive to vertical emittance and suitable for existing storage rings.
Area of Science:
- Physics
- Accelerator Physics
- Synchrotron Radiation
Background:
- Electron beam emittance is a critical parameter for synchrotron light source performance.
- Measuring vertical electron beam emittance accurately is challenging.
Purpose of the Study:
- To develop and validate a novel diagnostic for measuring picometer vertical electron beam emittances.
- To assess the applicability of this diagnostic to existing storage rings.
Main Methods:
- Utilized an APPLE-II type undulator phased for a horizontal magnetic field.
- Observed synchrotron radiation sensitive to vertical electron beam emittance.
- Analyzed undulator spectral peak height ratios against simulations.
Main Results:
- Achieved picometer vertical electron beam emittances at the Australian Synchrotron storage ring.
- Demonstrated the sensitivity of the undulator-based method to vertical emittance.
Conclusions:
- The developed undulator-based apparatus is an appropriate and novel diagnostic for vertical emittance.