Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Experiment Video

Updated: May 16, 2026

Anterior High-Resolution Optical Coherence Tomography in the Diagnosis and Therapeutic Monitoring of Ocular Surface Squamous Neoplasia
06:15

Anterior High-Resolution Optical Coherence Tomography in the Diagnosis and Therapeutic Monitoring of Ocular Surface Squamous Neoplasia

Published on: August 9, 2024

Software-assisted analysis during ocular health screening.

Anton M Kolomeyer1, Bernard C Szirth, Khadija S Shahid

  • 1The Institute of Ophthalmology and Visual Science, University of Medicine and Dentistry of New Jersey, Newark, NJ 07101, USA.

Telemedicine Journal and E-Health : the Official Journal of the American Telemedicine Association
|December 11, 2012
PubMed
Summary
This summary is machine-generated.

Related Concept Videos

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Operating Room Access: Survey of the American Society of Retina Specialists.

Journal of vitreoretinal diseases·2026
Same author

Geroprotective Agents, Including Glucagon-Like Peptide-1 Receptor Agonists, for Ocular Health.

Journal of ocular pharmacology and therapeutics : the official journal of the Association for Ocular Pharmacology and Therapeutics·2026
Same author

Underfunding of a Patient Copay Assistance Program and the Impact on Retinal Disease Care: Survey of ASRS Members.

Journal of vitreoretinal diseases·2026
Same author

Comparison of Medicaid vs Medicare Reimbursement Rates for Vitreoretinal Surgeries in the United States.

Journal of vitreoretinal diseases·2026
Same author

Time-Driven, Activity-Based Cost Analysis of Secondary Intraocular Lens Implantation.

Journal of vitreoretinal diseases·2026
Same author

Metformin Use and Risk of Glaucoma: A Systematic Review and Meta-Analysis.

American journal of ophthalmology·2026

Software-assisted analysis of non-mydriatic fundus images enables efficient ocular health screening. This method identified vision-threatening diseases in 10.2% of veterans, facilitating timely referrals.

Area of Science:

  • Ophthalmology
  • Medical Imaging
  • Digital Health

Background:

  • Ocular screening is crucial for early detection of vision-threatening diseases.
  • Non-mydriatic fundus photography offers a less invasive screening method.
  • Software-assisted analysis can enhance the efficiency and thoroughness of image interpretation.

Purpose of the Study:

  • To evaluate the utility of software-assisted analysis for non-mydriatic color fundus images in comprehensive ocular screening.
  • To assess the efficiency and diagnostic yield of this screening approach.

Main Methods:

  • Utilized software-driven filters (blue, green, red, emboss) to enhance non-mydriatic 45° color fundus images.
  • Conducted ocular health screening including intraocular pressure and visual acuity measurements.

More Related Videos

Using an Automated Hirschberg Test App to Evaluate Ocular Alignment
05:40

Using an Automated Hirschberg Test App to Evaluate Ocular Alignment

Published on: March 24, 2020

Assessing Early Stage Open-Angle Glaucoma in Patients by Isolated-Check Visual Evoked Potential
07:11

Assessing Early Stage Open-Angle Glaucoma in Patients by Isolated-Check Visual Evoked Potential

Published on: May 25, 2020

Related Experiment Videos

Last Updated: May 16, 2026

Anterior High-Resolution Optical Coherence Tomography in the Diagnosis and Therapeutic Monitoring of Ocular Surface Squamous Neoplasia
06:15

Anterior High-Resolution Optical Coherence Tomography in the Diagnosis and Therapeutic Monitoring of Ocular Surface Squamous Neoplasia

Published on: August 9, 2024

Using an Automated Hirschberg Test App to Evaluate Ocular Alignment
05:40

Using an Automated Hirschberg Test App to Evaluate Ocular Alignment

Published on: March 24, 2020

Assessing Early Stage Open-Angle Glaucoma in Patients by Isolated-Check Visual Evoked Potential
07:11

Assessing Early Stage Open-Angle Glaucoma in Patients by Isolated-Check Visual Evoked Potential

Published on: May 25, 2020

  • On-site medical director provided immediate feedback and referrals.
  • Main Results:

    • Analyzed color fundus images from 128 veterans.
    • Achieved an efficient image analysis rate of 26 eyes per hour.
    • Identified 13 individuals (10.2%) with findings suggestive of vision-threatening diseases, leading to referrals.

    Conclusions:

    • Software-assisted screening of non-mydriatic fundus images is effective for thorough and efficient ocular health evaluation.
    • This technology facilitates early detection and management of potentially sight-threatening conditions during screening events.