RPCA-based detection and quantification of motion artifacts in ECG signals
Rahul Kher1, Dipak Vala, Tanmay Pawar
1Department of Electronics & Communication Engineering, G H Patel College of Engineering & Technology, Vallabh Vidyanagar, Gujarat, India. rahul2777@yahoo.com
Abstract:
In this paper, a recursive principal component analysis (RPCA)-based algorithm is applied for detecting and quantifying the motion artifact episodes encountered in an ECG signal. The motion artifact signal is synthesized by low-pass filtering a random noise signal with different spectral ranges of LPF (low pass filter): 0-5 Hz, 0-10 Hz, 0-15 Hz and 0-20 Hz. Further, the analysis of the algorithm is carried out for different values of SNR levels and forgetting factors (α) of an RPCA algorithm. The algorithm derives an error signal, wherever a motion artifact episode (noise) is present in the entire ECG signal with 100% accuracy. The RPCA error magnitude is almost zero for the clean signal portion and considerably high wherever the motion artifacts (noisy episodes) are encountered in the ECG signals. Further, the general trend of the algorithm is to produce a smaller magnitude of error for higher SNR (i.e. low level of noise) and vice versa. The quantification of the RPCA algorithm has been made by applying it over 25 ECG data-sets of different morphologies and genres with three different values of SNRs for each forgetting factor and for each of four spectral ranges.
Related Concept Videos
Electrocardiogram
Three major waveforms are present in a typical ECG recording: the P wave, the QRS complex, and the T...
Instrumentation Amplifier
To overcome this challenge, an ECG machine utilizes an instrumentation amplifier. This specialized amplifier is...
ECG Interpretation of Rhythms
Components of the Electrocardiogram
The primary components of a normal ECG waveform in Normal sinus rhythm(NSR) include the P wave, PR interval, QRS complex, ST segment, T wave, and occasionally a U wave.
ECG waveforms are divided by vertical and horizontal lines at standard intervals.
The horizontal axis measures time and rate, and the vertical axis measures amplitude or voltage. When...
Correlation between ECG and Cardiac Cycle
A cardiac action potential originates in the SA node and spreads throughout the atria and the AV node in approximately 0.03 seconds. This results in the P wave in an ECG and triggers atrial contraction. The action potential is then briefly slowed at the AV node, allowing the atria to contract and fill the ventricles with blood before...