Comprehensive assessment of gastric emptying with a stable isotope breath test
A E Bharucha1, M Camilleri, E Veil
1Clinical Enteric Neuroscience Translational and Epidemiological Research and College of Medicine, Mayo Clinic, Rochester, MN 55905, USA.
Background:
The [(13)C]-Spirulina platensis gastric emptying breath test (GEBT) with five samples is accurate relative to scintigraphy. This study was primarily designed to further validate this GEBT using a slightly different process for incorporating [(13)C] in Spirulina and to evaluate the utility of additional samples for assessing early gastric emptying.
Methods:
After a 223 kcal, test meal labeled with (99m) Tc and [(13)C]-S. platensis, scintigraphic images, and five breath samples (45, 90, 120, 180, and 240 min, GEBT5) were collected in 14 controls (Part A). In Part B, nine breath samples were collected at 15, 30, 45, 60, 90, 120, 150, 180, and 240 min (GEBT9) in 30 subjects (15 controls, 15 dyspepsia). Using correlation between [(13)C] breath excretion and scintigraphic emptying, lag time (t(10), time for 10% emptying), emptying at 30 min (GE(30)), and half time (t(50)) were estimated for GEBT5 (Parts A and B) and GEBT9 (Part B).
Key Results:
Half time values for scintigraphy, GEBT5, and GEBT9 were highly concordant. t(10) by GEBT9 (90%CI, 6-15 min) was more strongly correlated [CCC 0.80 (95% CI, 0.63-0.90)] with scintigraphy (90% CI, 5-12 min), than GEBT5 [10-19 min, CCC 0.73 (95% CI, 0.54-0.85)]. The correlation between estimated values (GEBT9) and linearly interpolated values (GEBT5) was closer at 60 [CCC 0.95 (95% CI, 0.91-0.97)] than 30 min [CCC 0.81 (95% CI, 0.71-0.89)].
Conclusions & Inferences:
The [(13) C]-S. platensis GEBT can accurately measure GE. While 5- and 9-samples are equally accurate for measuring t(50), GEBT9 provides a more comprehensive assessment of early GE (t(10) and GE(30)).
More Related Videos
Related Concept Videos
Imaging Studies III: Gastrointestinal Motility Studies and Virtual Colonoscopy
Radionuclide Testing
Radionuclide testing is a sophisticated medical technique for assessing gastrointestinal motility. It focuses on gastric emptying and colonic transit time. Radioactive markers track the movement of food through the digestive system, providing insights into gastrointestinal disorders.
In gastric emptying studies, a meal's liquid and solid...
Gastric Emptying
Upper GI Series: Barium Swallow
Purpose and Procedure
Patients undergoing this procedure ingest a liquid containing barium sulfate with a chalky...
Serum Laboratory Studies, Stool Test, Breath Test
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Assessment of the Gastrointestinal System I: Subjective Data
Health History
The initial step in assessing the GI system is obtaining a comprehensive health history. This includes inquiring about the patient's history or presence of problems related to...