Related Experiment Video
Updated: May 16, 2026

Ultrahigh Density Array of Vertically Aligned Small-molecular Organic Nanowires on Arbitrary Substrates
Published on: June 18, 2013
Optimization of electrode size for aluminum-nitride matrix ultrasonic transducers in the frequency range above 200
Yangjie Wei1, Thomas Herzog, Henning Heuer
1Graduate School of Chinese Academy of Science, State Key Laboratory of Robotics, Shenyang Institute of Automation, CAS, Shenyang, China. weiyangjie@sia.cn
Abstract:
This paper describes an optimization method of the top electrode size for a thin film matrix ultrasonic transducer (M-UT) in the frequency range above 200 MHz. The goal of this work is to design an optimal top electrode size for an M-UT providing the maximal output peak-peak voltage (V(PP)) and the maximal signal-to-noise ratio (SNR) without additional electrical impedance matching. In order to reduce the complexity of the M-UT with more than 1000 elements, an intrinsic matching by electrode size variation is necessary. However, the size of a single element top electrode for an M-UT is related to the number of elements within a targeted sensor area, V(PP) and SNR of the transducer. In this paper, varying the active area of the top electrode from 0.09 to 25 mm(2) shows that for an Al-AlN-Al on silicon wafer configuration connected with a JSR Ultrasonics pulser/receiver (50 ohms), the optimal electrode size is 1 mm(2). With the optimal size electrode, the maximum output V(PP) of 0.08 V and the SNR of 42.93 dB are achieved at the resonance frequency of 225 MHz, and the bandwidth is 16.21 MHz.