A novel metal artifact reducing method for cone-beam CT based on three approximately orthogonal projections
Qingli Wang1, Liang Li, Li Zhang
1Department of Engineering Physics, Tsinghua University, Beijing 100084, People's Republic of China.
Abstract:
Metal artifacts remain a challenge for computed tomography (CT) reconstruction, especially for medical CT, in which the radiation dose for patients is strictly limited. This study presents a novel method of reducing the metal artifacts for cone-beam CT by renovating the metal areas in the 2D cone-beam projection. We first calculate the 3D coordinates of all the metallic implants, which will then be projected into the projection images in each angle as the metal seed points (MSPs), increasing the precision of the segmentation of the metal areas. Different from the existing methods of calculating the metal positions with two projection images, we proposed a new method to calculate the 3D coordinates of all the metallic implants using three different projection images that are nearly orthogonal. One is the parallel-beam projection image along the Z-axial direction (i.e. along the rotation axis) calculated by the projection synthesizing method, while the other two are the cone-beam projections at two different views chosen from the scanned data. The three nearly orthogonal views will greatly help to accurately locate the metallic implants when there is more than one implant in the object. Then the MSPs can be located in each projection by geometry calculations. The region growing segmentation method and the bilinear interpolation method are used to modify the projection areas of the metallic implants. Experimental studies demonstrate that this method is accurate in locating MSPs and efficient in reducing metal artifacts.
More Related Videos
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Electron Microscope Tomography and Single-particle Reconstruction
Electron Tomography
Electron tomography can be performed either in TEM or STEM (scanning transmission...