Related Experiment Video
Updated: May 16, 2026

An Implantable System For Chronic In Vivo Electromyography
Published on: April 21, 2020
Bilateral vocal palsy following coin cell lithium battery ingestion: a case report and review
Mathieu Simonin1, Irène D'Agostino, Mélanie Lebreton
1Service de Réanimation Chirurgicale Pédiatrique, Hôpital Necker Enfants-Malades, Assistance Publique- Hôpitaux de Paris, Faculté de Médecine, Université Paris-Descartes, 149, Rue de Sèvres, 75743 Paris Cedex 15, France.
Unlabelled:
Button battery ingestion in children is not a rare occurrence and may be unwitnessed and can be soon life-threatening or responsible for severe sequelae. We report herein an original history of previously healthy 16-month-old boy with an unwitnessed and misdiagnosis of lithium cell coin battery ingestion which leads to bilateral vocal palsy. The patient underwent a unilateral posterior cordotomy and was successfully extubated.
Conclusion:
Early recognition of a lithium cell coin battery for rapid removal, even if insufficient at first, is the main condition to limit complications. Unusual upper respiratory distress in a young child should alert practitioners in performing a chest and neck X-ray without undue delay.