Temperature-programmed sputtered micromachined gas chromatography columns: an approach to fast separations in
R Haudebourg1, J Vial, D Thiebaut
1Laboratoire Sciences Analytiques, Bioanalytiques et Miniaturisation, ESPCI Paristech, CNRS UMR PECSA, Paris, France.
Abstract:
In a previous study, a new stationary phase deposition technique for micromachined gas chromatography columns was presented. The rerouting of the sputtering technique to this purpose enabled collective and reproducible fabrication of microcolumns in a silicon wafer. Silica-sputtered micromachined columns showed promising separations of light alkanes in isothermal conditions. In order to go beyond the limitations of isothermal separations, the columns were equipped with sputtered platinum filaments to enable high-speed and low-power temperature programming. The separation performances of temperature-programmed silica- or graphite-sputtered microcolumns were investigated: a separation of light alkanes (C1-C5) was completed in 9 s, and heavier alkanes (until C9), cyclic, isomeric, and unsaturated hydrocarbons were also successfully separated. Versatility of these microcolumns was demonstrated with a high-temperature C1-C2 separation and a C1-C5 separation with nitrogen as carrier gas instead of helium. By matching the requirements of a gas chromatography-based monitoring sensor, in terms of low-cost and industry-ready fabrication process, fast temperature programming and analysis, low power consumption, and good versatility (ambient temperature, carrier gas), these columns should be used in various applications related to oilfield gas analyses.
More Related Videos
11:44Qualitative Characterization of the Aqueous Fraction from Hydrothermal Liquefaction of Algae Using 2D Gas Chromatography with Time-of-flight Mass Spectrometry
Published on: March 6, 2016
13:36Simple In-House Ultra-High Performance Capillary Column Manufacturing with the FlashPack Approach
Published on: December 4, 2021
Related Concept Videos
Gas Chromatography: Types of Columns and Stationary Phases
For an analyte to remain on the column for a sufficient amount of time, it must exhibit some level of compatibility (or...
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a column.
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall. The coating...
Gas Chromatography: Sample Injection Systems
Two primary injection methods are used...
Supercritical Fluid Chromatography
SFC utilizes a supercritical fluid mobile phase,...
Principles Of Column Chromatography