Pump injector system applied to targeted post-mortem coronary artery angiography
Claire Robinson1, Jade Barber, Jasmin Amoroso
1Imaging Department, Leicester Royal Infirmary, University Hospitals of Leicester, Leicester LE27LX, UK.
International Journal of Legal Medicine
|December 13, 2012
Summary
This study introduces an automatic pump injector for targeted post-mortem computed tomography angiography (PMCTA) to improve coronary artery visualization after death. This method overcomes limitations of manual injection, providing better contrast and mimicking physiological pressure.
Area of Science:
- Forensic Medicine
- Radiology
- Cardiovascular Imaging
Background:
- Investigating coronary arteries post-mortem is crucial for determining cause of death.
- Traditional manual injection in post-mortem computed tomography angiography (PMCTA) has limitations, including poor contrast and failure to replicate physiological arterial pressure.
- Iodinated contrast media used in manual PMCTA dissipates rapidly, compromising image quality.
Purpose of the Study:
- To report the development and protocol for using a clinical automatic pump injector for targeted PMCTA.
- To enhance the visualization of coronary arteries in cadavers.
- To overcome the limitations associated with manual contrast media injection in PMCTA.
Main Methods:
- Adaptation of a clinical automatic pump injector for post-mortem use.
- Development of a final protocol based on experience from 74 cases.
- Injection of air and positive contrast media into coronary arteries of cadavers using the pump system.
Main Results:
- The automatic pump injector system successfully visualizes coronary arteries.
- The protocol allows for the translation of clinical pump technology into autopsy practice.
- The method aims to provide optimal contrast and mimic physiological arterial pressure.
Conclusions:
- Clinical automatic pump injectors are suitable for targeted post-mortem computed tomography angiography (PMCTA).
- This technique offers an improved method for investigating coronary arteries after death.
- The developed protocol provides a standardized approach for utilizing pump injectors in forensic radiology.