Related Experiment Video
Updated: Feb 16, 2026

Individualized Stem-positioning in Calcar-guided Short-stem Total Hip Arthroplasty
Published on: February 27, 2018
Risk factors for ceramic liner fracture after total hip arthroplasty
Francesco Traina1, Marcello De Fine, Barbara Bordini
1Department of Hip and Knee Surgery, Rizzoli Orthopaedic Institute, Bologna, Italy.
Abstract:
The aim of this study was to detect risk factors for ceramic liner fractures. 26 cementless ceramic on ceramic (COC) total hip arthroplasties (THA) revised because of ceramic liner fracture in 24 patients were compared with 49 well-functioning COC THA performed in 49 patients. Demographic parameters, type of ceramic of the liner, size and neck length of the femoral head, cup abduction angle, cup anteversion, femoral off-set, height of the centre of rotation and the incidence of noisy hips during follow-up examination were compared. A greater number of cups placed outside the optimal range of cup anteversion was found in the fracture group (p = 0.03). An audible noise was detected in 21 cases (80.7%) in the fracture group and in 3 cases (6.1%) in the non-fracture group (p = 0.001). A cup anteversion angle out of the optimal range of 15˚+/-10˚ was found to be a risk factor for ceramic liner fracture and the presence of a noisy hip frequently anticipated the failure. In our opinion neck-to-cup impingement with head subluxation and edge loading on the liner rim could have an important role in the onset of noise and subsequent liner failure, and cup malposition contributes to this mechanism of failure.
Related Concept Videos
Drug Toxicity: Risk factors
Factors Affecting the Risk of Infection
The integrity and count of the white blood cells help the body resist pathogens and fight infection. When impaired, it reduces the body's resistance to pathogens. The acidic pH levels of the gastrointestinal, genitourinary tracts, and skin...
Relative Risk
Fractures: Bone Repair
Minor fractures with no bone displacement are treated by immobilizing the fractured bone using a cast or splint. However, in the case of fractures with displaced bones, the broken bones are repositioned before immobilization to ensure successful healing without deformation and loss of function. The realignment of fractured bone ends is performed through a process called reduction. If the...
Transcription Factors
Electrolytes: van't Hoff Factor
The colligative properties of a solution depend only on the number, not on the identity, of solute species dissolved. The concentration terms in the equations for various colligative properties (freezing point depression, boiling point elevation, osmotic pressure) pertain to all solute species present in the solution. Nonelectrolytes dissolve physically without dissociation or any other accompanying process. Each molecule that dissolves yields one...