Causes of nonlinearity of the oxygen uptake efficiency slope: a prospective study in patients with chronic heart
Victor M Niemeijer1, Marcel van 't Veer, Goof Schep
1Máxima Medical Centre, Veldhoven, The Netherlands.
Background:
The oxygen uptake efficiency slope (OUES) is an exercise parameter with strong prognostic value in the heart failure population. Yet, the optimal determination method of OUES remains unclear. The purpose of the present study was to investigate the influence of the ventilatory anaerobic threshold (VAT) and occurrence of a plateau in oxygen uptake (VO2) on determination of OUES from submaximal exercise data in patients with chronic heart failure (CHF).
Methods And Results:
Ninety-eight CHF patients (New York Heart Association class II-III) were included. All patients performed a symptom-limited exercise test with gas exchange analysis on a cycle ergometer. VAT was determined by the V-slope method and OUES was derived via least-squares linear regression using 100% (OUES100), 90% (OUES90), and 75% (OUES75) of exercise duration, and, in addition, by using only the first 50% of data points preceding VAT (OUES½VAT), all data preceding VAT (OUESVAT), and only data following VAT (OUESpostVAT). Whereas OUESVAT (1720 ± 430 ml/min/log(l/min)), OUES75 (1811 ± 476 ml/min/log(l/min)), and OUESpostVAT (1742 ± 564 ml/min/log(l/min)) were not significantly different from OUES100 (1767 ± 542 ml/min/log(l/min)), OUES½VAT (1500 ± 314 ml/min/log(l/min)) was significantly lower than all other values (p < 0.01). When a VO2 plateau was present, OUES100 was lower than OUES90 (p < 0.05).
Conclusions:
The study results indicate that OUES values should be interpreted with caution when CHF patients do not reach the ventilatory anaerobic threshold or when a VO2 plateau is present.
More Related Videos
08:35Oxygenation-sensitive Cardiac MRI with Vasoactive Breathing Maneuvers for the Non-invasive Assessment of Coronary Microvascular Dysfunction
Published on: August 17, 2022
09:04Skeletal Muscle Neurovascular Coupling, Oxidative Capacity, and Microvascular Function with 'One Stop Shop' Near-infrared Spectroscopy
Published on: February 20, 2018
Related Concept Videos
Nonlinear Pharmacokinetics: Causes of Nonlinearity
Nonlinear drug absorption can occur when the process is rate-limited by solubility, carrier-mediated transport systems, or saturation of the presystemic gut wall or hepatic metabolism. For instance, high doses of riboflavin...
Nonlinear Pharmacokinetics: Overview
Nonlinearity can arise due to the saturation of plasma protein-binding or...
Heart Failure VI: Adjunct Therapies
Pathophysiology of Heart Failure
Heart Failure I: Introduction
Heart Failure II: Pathophysiology