Related Experiment Video
Updated: Feb 26, 2026

Structured Approach to Colonoscopy Technique Optimization: A Single-Center Experience with Novice Endoscopists
Published on: July 11, 2025
The effect on colon visualization during colonoscopy of the addition of simethicone to polyethylene
Rebecca Matro1, Keegan Tupchong, Constantine Daskalakis
1Division of Gastroenterology and Hepatology, Thomas Jefferson University, Philadelphia, PA, USA.
Objectives:
Colonic bubbles associated with polyethylene glycol-electrolyte solution (PEG-ELS) are common and obscure mucosal visualization. This study aimed to determine whether adding simethicone decreases the incidence of bubbles.
Methods:
Prospective, single-blind, randomized comparison of split dose PEG-ELS vs. PEG-ELS+simethicone (PEG-S) for outpatient colonoscopy. Bubble severity for colonic segments was assessed on withdrawal as A=no/minimal bubbles, B=moderate bubbles/interfere with detecting 5 mm polyp, C=severe bubbles/interfere with detecting 10 mm polyp. Primary end point was Grade B or C bubbles in any colon segment. Secondary end points were cleansing quality, incidence and severity of side effects, and polyp detection.
Results:
One hundred and thirty nine patients enrolled; 13 withdrew before colonoscopy. Of 123 patients evaluated, 62 took PEG-S and 61 PEG-ELS. The incidence of grade B or C bubbles was much lower with PEG-S compared with PEG-ELS (2% vs. 38%; P=0.001). Overall cleansing (excellent or good) quality was not significantly different for either the whole colon (89% PEG-ELS, 94% of PEG-S, P=0.529) or right colon (88% PEG-ELS, 94% PEG-S, P=0.365). More PEG-S patients had excellent rather than good preps (whole colon 53% vs. 28%, P=0.004; right colon 53% vs. 35%, P=0.044). Need for any flushing was less with PEG-S (38% vs. 70%, P=0.001). The groups were not significantly different with respect to total procedure and withdrawal times, incidence or severity of side effects, or number of polyps/patient or adenomas/patient.
Conclusions:
Adding simethicone to PEG-ELS effectively eliminates bubbles, substantially reduces the need for flushing, and results in more excellent preparations.
More Related Videos
09:42Murine Endoscopy for In Vivo Multimodal Imaging of Carcinogenesis and Assessment of Intestinal Wound Healing and Inflammation
Published on: August 26, 2014
15:49Flexible Colonoscopy in Mice to Evaluate the Severity of Colitis and Colorectal Tumors Using a Validated Endoscopic Scoring System
Published on: October 16, 2013
Related Concept Videos
Imaging Studies III: Gastrointestinal Motility Studies and Virtual Colonoscopy
Radionuclide Testing
Radionuclide testing is a sophisticated medical technique for assessing gastrointestinal motility. It focuses on gastric emptying and colonic transit time. Radioactive markers track the movement of food through the digestive system, providing insights into gastrointestinal disorders.
In gastric emptying studies, a meal's liquid and...
Endoscopic Procedures II: Colonoscopy
Endoscopic Procedures III: Video Capsule Endoscopy
Drugs Affecting GI Tract Motility: Other Laxatives
Osmotic or saline laxatives, like magnesium hydroxide or milk of...
Endoscopic Procedures IV: Sigmoidoscopy and Laproscopy
Sigmoidoscopy
Sigmoidoscopy is a diagnostic procedure that uses a flexible sigmoidoscope equipped with a light source and camera to examine the rectum and sigmoid colon. The procedure involves inserting the tube through the anus...
Lower GI Series: Barium Enema
Procedure Details
The examination begins by inserting a lubricated rectal tube into the patient's rectum to administer a radiopaque barium solution. The barium flow is carefully...