Related Experiment Video
Updated: May 16, 2026

Drug-Induced Sleep Endoscopy (DISE) with Target Controlled Infusion (TCI) and Bispectral Analysis in Obstructive Sleep Apnea
Published on: December 6, 2016
Serum bicarbonate level improves specificity of STOP-Bang screening for obstructive sleep apnea
Frances Chung1, Edmond Chau1, Yiliang Yang1
1Department of Anesthesiology, Toronto Western Hospital, University Health Network, University of Toronto, Toronto, ON, Canada.
Background:
The STOP-Bang questionnaire is a validated screening tool for the identification of surgical patients with obstructive sleep apnea (OSA). A STOP-Bang score ≥ 3 is highly sensitive but only moderately specific. Apnea/hypopnea during sleep can lead to intermittent hypercapnia and may result in serum bicarbonate (HCO₃⁻) retention. The addition of serum HCO₃⁻ level to the STOP-Bang questionnaire may improve its specificity.
Methods:
Four thousand seventy-seven preoperative patients were approached for consent and screened by the STOP-Bang questionnaire. Polysomnography was performed and preoperative HCO₃⁻ level was collected in 384 patients. Study participants were randomly assigned to a derivation or validation cohort. Predictive parameters (sensitivity, specificity, positive and negative predictive values) for STOP-Bang score and serum HCO₃⁻ level were calculated.
Results:
In the derivation cohort, with a STOP-Bang score ≥ 3, the specificity for all OSA, moderate/severe OSA, and severe OSA was 37.0%, 30.4%, and 27.7%, respectively. HCO₃⁻ level of 28 mmol/L was selected as a cutoff for analysis. With the addition of HCO₃⁻ level ≥ 28 mmol/L to the STOP-Bang score ≥ 3, the specificity for all OSA, moderate/severe OSA, and severe OSA improved to 85.2%, 81.7%, and 79.7%, respectively. Similar improvement was observed in the validation cohort.
Conclusion:
Serum HCO₃⁻ level increases the specificity of STOP-Bang screening in predicting moderate/severe OSA. We propose a two-step screening process. The first step uses a STOP-Bang score to screen patients, and the second step uses serum HCO₃⁻ level in those with a STOP-Bang score ≥ 3 for increased specificity.
Related Concept Videos
Sleep Apnea
The condition is more prevalent among...
Diagnosing Acidosis and Alkalosis
First, the pH level is assessed to determine whether the blood pH is normal (7.35–7.45), low (acidosis), or high (alkalosis).
Next, the PCO2 and HCO3− values are examined to...
Bicarbonate-Carbonic Acid Buffer
Blood Studies I: ABG and VBG
Arterial Blood Gas (ABG)
Arterial Blood Gas (ABG) studies are crucial for assessing the lungs' ability to supply oxygen and remove carbon dioxide, reflecting the patient's ventilation status. They also help understand the kidneys' capacity to reabsorb or...
Respiratory Regulation of Acid-Base Balance
When carbon dioxide levels increase in the blood, more H+ and HCO3⁻ are produced, leading to a...
Assessment of Diffusion and Perfusion
The Role of Diffusion in Respiration