Related Experiment Video
Updated: May 16, 2026

05:28
Clinical Imaging of Microwave Mammography
Published on: November 14, 2025
Pressure and breast thickness in mammography--an exploratory calibration study
P Hogg1, M Taylor, K Szczepura
1School of Health Sciences, University of Salford, Salford, UK. P.Hogg@Salford.ac.uk
The British Journal of Radiology
|December 15, 2012
Summary
This study calibrated mammography machines to standardize breast compression pressure, suggesting 13 decanewtons (daN) as an optimal termination pressure. This aims to improve image quality and patient experience by reducing pressure variations.
Area of Science:
- Radiological imaging and medical device calibration.
- Biomedical engineering and clinical practice.
Background:
- Mammography machine pressure application varies, potentially impacting image quality and patient comfort.
- Standardized pressure is crucial for consistent diagnostic accuracy in mammography.
Purpose of the Study:
- To calibrate a mammography machine using patient compression data.
- To establish pressure-thickness characteristics for improved consistency in mammography.
Main Methods:
- Collected compression data (breast thickness, density, pressure) from 235 patients undergoing mammography.
- Recorded pressure in decanewtons (daN) from 5 daN upwards, noting breast thickness at each increment.
- Analyzed data using polynomial trend lines and considered differences between small and medium/large compression paddles.
Main Results:
- Developed pressure-thickness graphs for mammography, showing changes in breast thickness relative to applied pressure.
- Identified no significant difference in breast density but noted variations related to paddle size.
- Proposed 13 daN as a potential target termination pressure for mammography based on the calibration data.
Conclusions:
- Calibrated mammography machine pressure-thickness data can guide practice to minimize inter-practitioner pressure variations.
- This standardization can enhance patient experience and reduce variability in mammographic image quality.
- Novel pressure-thickness graphs are now available to assist mammographers in applying optimal compression pressure.