Successful management of auto knotted intravesical infant feeding tube by minimal invasive technique

Sidharth Khullar1, Molay K Bera, Anup K Kundu

  • 1Department of Urology, IPGME and R, Kolkata, West Bengal, India.

Insights

A child experienced acute urinary retention caused by a knotted infant feeding tube inside the bladder. Endoscopic surgery successfully resolved this rare complication.

Area of Science:

  • Pediatric Urology
  • Minimally Invasive Surgery

Background:

  • Infant feeding tubes are common medical devices used for nutritional support in neonates and infants.
  • Complications, though rare, can arise from indwelling devices, necessitating prompt diagnosis and management.

Observation:

  • A case is presented of a child who developed acute urinary retention.
  • The cause was identified as an infant feeding tube that had auto-knotted within the urinary bladder.

Findings:

  • The intravesical auto-knotting of an infant feeding tube is a previously undescribed cause of acute urinary retention in a child.
  • Successful management was achieved using a minimally invasive endoscopic approach.

Implications:

  • This case highlights a rare but significant complication associated with infant feeding tubes.
  • Endoscopic intervention offers a safe and effective treatment option for such intravesical foreign body complications.