Related Experiment Video
Updated: May 15, 2026

A Strategy for Sensitive, Large Scale Quantitative Metabolomics
Published on: May 27, 2014
An improved mass spectrometry-based measurement of NO metabolites in biological fluids
Xingbin Yang1, Catherine P Bondonno, Adeline Indrawan
1College of Food Engineering and Nutritional Science, Shaanxi Normal University, Xi'an 710062, China.
Abstract:
Assessment of NO metabolism in vivo relies on the accurate measurement of its metabolites nitrite (NO(2)(-)), nitrate (NO(3)(-)), and nitrosothiols (RSNOs) in biological fluids. We report a sensitive method to simultaneously determine NO(2)(-) and NO(3)(-) in biological matrixes. Tetraoctylammonium was used to catalyze the complete conversion of NO(2)(-) and NO(3)(-) to stable pentafluorobenzyl (PFB) derivatives directly from aqueous acetone medium before gas chromatography and negative-ion chemical ionization mass spectrometry (GC/NICI/MS). This catalyst dramatically improved the yield of PFB derivatives for NO(2)(-) (4.5 times) and NO(3)(-) (55 times) compared to noncatalyzed derivatization methods. Analysis was performed using (15)N-labeled internal standards by selected-ion monitoring at m/z 46 for fragment NO(2)(-) and m/z 47 for its isotope analogue, (15)NO(2)(-), and m/z 62 for NO(3)(-) and m/z 63 for (15)NO(3)(-). This method allowed specific detection of both PFB derivatives over a wide dynamic range with a limit of detection below 4.5 pg for NO(2)(-) and 2.5 pg for NO(3)(-). After the specific conversion of RSNOs by HgCl(2) to NO(2)(-), this GC/NICI/MS analysis was used to measure RSNOs in plasma. A further comparison with the widely used tri-iodide chemiluminescence (I(3)(-)-CL) assay indicated that the GC/MS assay validated the lower physiological RSNO and nitrite levels reported using I(3)(-)-CL detection compared with values obtained using UV-photolysis methods. Plasma levels of RSNOs determined by GC/MS and I(3)(-)-CL were well correlated (r = 0.8). The improved GC/MS method was successfully used to determine the changes in plasma, urinary, and salivary NO(2)(-) and NO(3)(-) as well as plasma RSNOs in humans after either a low-NO(3)(-) or a high-NO(3)(-) meal.
More Related Videos
07:54Capillary Electrophoresis Mass Spectrometry Approaches for Characterization of the Protein and Metabolite Corona Acquired by Nanomaterials
Published on: October 27, 2020
11:00Untargeted Metabolomics from Biological Sources Using Ultraperformance Liquid Chromatography-High Resolution Mass Spectrometry (UPLC-HRMS)
Published on: May 20, 2013
Related Concept Videos
Mass Spectrometry: Overview
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...
MALDI-TOF Mass Spectrometry