Precision of pulmonary vein diameter measurements assessed by CE-MRA and steady-state-free precession imaging
Related Experiment Video
Updated: May 15, 2026

Three-Dimensional Echocardiographic Method for the Visualization and Assessment of Specific Parameters of the Pulmonary Veins
Published on: October 28, 2020
Michael Groth1, Peter Bannas, Marc Regier
1Department of Diagnostic and Interventional Radiology, Center for Radiology and Endoscopy, University Medical Center Hamburg-Eppendorf, Martinistr. 52, 20246 Hamburg, Germany. groth.michael@googlemail.com
Objective:
Pulmonary vein (PV) diameter assessment is important for planning and follow-up of PV ablation in atrial fibrillation. Therefore, the aim of our study was to evaluate inter- and intraobserver reliability of PV diameter measurements by contrast-enhanced magnetic resonance angiography (CE-MRA) and ECG-gated 2D multislice unenhanced steady-state-free precession sequences (multislice SSFP).
Methods:
Sixty PV diameters in 17 consecutive patients were measured in transverse and coronal orientation with CE-MRA and multislice SSFP by two observers. Statistics to evaluate inter- and intraobserver reliability included Bland-Altman analysis and F-test.
Results:
Intraobserver limits of agreement (LAG) ranged between ±0.50 cm (transverse) and ±0.86 cm (coronal) for CE-MRA versus ±0.40 cm (transverse) and ±0.67 cm (coronal) for multislice SSFP. Interobserver agreement showed LAG ranging between ±0.59 cm (transverse) and ±0.83 cm (coronal) for CE-MRA versus ±0.34 cm (transverse) and ±0.75 cm (coronal) for multislice SSFP. Intra- and interobserver variances did not reveal significant differences between CE-MRA and multislice SSFP in any orientation (all p-values >0.05).
Conclusion:
Multislice SSFP and CE-MRA enable comparable precision of PV diameter measurements. However, both methods reveal a wide range of intra- and interobserver agreement, which has to be thoroughly considered in clinical use.
Key Points:
• Unenhanced magnetic resonance imaging can now provide measurement of pulmonary vein diameters • Steady-state-free precession offers a new method of performing unenhanced MR imaging • Both unenhanced and enhanced MRI measurements show wide intra- and interobserver variation • PV diameter measurements assessed by MRI have to be interpreted with care • Nevertheless, unenhanced MRI might replace some CT examinations for pulmonary vein demonstration.
Insights
Unenhanced magnetic resonance imaging (MRI) and contrast-enhanced MRI provide comparable pulmonary vein diameter measurements. However, both methods show significant intra- and interobserver variability, requiring careful clinical interpretation.
Area of Science:
- Radiology
- Cardiovascular Imaging
- Medical Physics
Background:
- Pulmonary vein (PV) diameter is crucial for planning and follow-up of atrial fibrillation ablation.
- Accurate PV diameter assessment is essential for effective treatment strategies.
Purpose of the Study:
- To evaluate the inter- and intraobserver reliability of PV diameter measurements.
- To compare contrast-enhanced magnetic resonance angiography (CE-MRA) with ECG-gated 2D multislice unenhanced steady-state-free precession (multislice SSFP) sequences.
Main Methods:
- Sixty PV diameters in 17 patients were measured using both CE-MRA and multislice SSFP.
- Measurements were performed in transverse and coronal orientations by two independent observers.
- Inter- and intraobserver reliability were assessed using Bland-Altman analysis and F-test statistics.
Main Results:
- Intraobserver limits of agreement ranged from ±0.40 cm to ±0.86 cm for both methods.
- Interobserver agreement showed limits of agreement between ±0.34 cm and ±0.83 cm.
- No significant differences in intra- or interobserver variances were found between CE-MRA and multislice SSFP (p > 0.05).
Conclusions:
- Multislice SSFP and CE-MRA offer comparable precision for PV diameter measurements.
- Both techniques exhibit considerable intra- and interobserver variability.
- PV diameter measurements by MRI require careful consideration in clinical practice.