Related Experiment Video
Updated: May 15, 2026

Benefits of Cardiac Resynchronization Therapy in an Asynchronous Heart Failure Model Induced by Left Bundle Branch Ablation and Rapid Pacing
Published on: December 11, 2017
Does reducing unnecessary right ventricular pacing improve sympathetic activity and innervation of heart in sinus
Mihoko Miyamoto1, Yuichiro Kimura, Junya Hosoda
1Department of Medical Science and Cardiorenal Medicine, Yokohama City University Graduate School of Medicine, Kanagawa, Japan.
Abstract:
Ventricular desynchronization imposed by ventricular pacing causes regional disturbances of adrenergic innervation in the left ventricular myocardium and increases the risk of heart failure and atrial fibrillation (AF) in patients with sinus node disease (SND). As a result, decreased iodine-123 metaiodobenzylguanidine (I-(123 )MIBG) uptake occurs in patients with an implanted permanent pacemaker. Fourteen SND patients with an implanted pacemaker equipped with an algorithm for reducing unnecessary right ventricular pacing (RURVP) were enrolled. Pacemakers were programmed to RURVP mode for the first 12 weeks, and then reprogrammed to DDD for the last 12 weeks. At the end of each mode, data on cumulative percent ventricular pacing (%Vp), atrial high rate episodes (%AHR), I-(123 )MIBG myocardial scintigraphy, brain natriuretic peptide (BNP), human atrial natriuretic peptide (hANP), and myocardial damage indices typified by troponin T and C-reactive protein (CRP) were collected. %Vp was lower in RURVP than in DDD (0.2% versus 95.7%, P = 0.00098). BNP, hANP, troponin T, and CRP did not differ significantly between the pacing modes. However, I-(123 )MIBG findings of patients with full ventricular pacing in DDD improved in RURVP. In contrast, among patients without full ventricular pacing in DDD, their I-(123 )MIBG findings did not differ significantly between the pacing modes. In SND patients with normal cardiac function and intact atrioventricular conduction, the reduction of %Vp in RURVP was due to the reduction of ineffective pacing and fusion pacing in DDD. Therefore, these 2 types of pacing do not affect cardiac pump function.
More Related Videos
07:49A Pacing-Controlled Procedure for the Assessment of Heart Rate-Dependent Diastolic Functions in Murine Heart Failure Models
Published on: July 21, 2023
09:20Microelectrode Array Recording of Sinoatrial Node Firing Rate to Identify Intrinsic Cardiac Pacemaking Defects in Mice
Published on: July 5, 2021
Related Concept Videos
Mitral Valve Prolapse III: Nursing Management
Mitral Valve Prolapse II: Assessment and Management
Cardiomyopathy III: Hypertrophic Cardiomyopathy
Heart Failure Drugs: β-Blockers
Heart Failure Drugs: Inhibitors of Renin-Angiotensin System
Cardiomyopathy V: Interprofessional Care